SAN ANTONIO, TX ·
OSHA Inspection: MARBROS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARBROS, LLC in 623 NEW LAREDO HIGHWAY, SAN ANTONIO, TX 78211 (NAICS 311613). OSHA activity number 339464307.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARBROS, LLC
- Site address
- 623 NEW LAREDO HIGHWAY
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78211
- Mailing
- 623 NEW LAREDO HIGHWAY, SAN ANTONIO, TX 78211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311613
- Employees
- 20
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Nov 14, 2013
- Abate by
- Dec 4, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Guards on machines were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, and rotating parts: On or about November 5, 2013, and at times prior thereto, an employee in the spice mixing room was exposed to an amputation hazard while using a Univex M60 mixer without a guard for the rotating auger.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.305 G02 III
- Issued
- Nov 14, 2013
- Abate by
- Dec 4, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: On or about November 5, 2013, and at times prior thereto, an employee in the spice mixing room was exposed to an electrical hazard while using a Univex M60 mixer that did not have strain relief on the 220V flexible power feed cord.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
More inspections in this industry (NAICS 311613)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339464307.