Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: SAC INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SAC INC. in 1060 RIDGEVIEW DR., INVERNESS, IL 60067 (NAICS 238170). OSHA activity number 339464612.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SAC INC. for free Get an email when a new federal OSHA severe-injury report for SAC INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SAC INC.
Site address
1060 RIDGEVIEW DR.
City
INVERNESS
State
IL
ZIP
60067
Mailing
9009 79TH AVE, HICKORY HILLS, IL 60457
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
Private (A)

7 citations on file for this inspection.

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 26, 2013
Abate by
Dec 9, 2013
Penalty
Initial $2,800 · Current $1,180 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:      a)  Employees working from a ladder jack scaffold were exposed to a fall hazard of approximately 22 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $1180.29
  • · Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 26, 2013
Abate by
Dec 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a)  Employees installing siding on a newly constructed single family home were exposed to fall hazards of approximately 11.4 feet from the eave of the roof.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.452 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 26, 2013
Abate by
Dec 9, 2013
Penalty
Initial $2,800 · Current $1,035 Reduced
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m):      a)  Employees were working from a ladder jack scaffold platform that was approximatley 22 feet high above hardened ground.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $1035.21
  • · Z (S) $2800

1926.452 K02

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 26, 2013
Abate by
Dec 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.452(k)(2): All ladders used to support ladder jack scaffolds shall meet the requirements of subpart X of this part -- Stairways and Ladders, except that job-made ladders shall not be used to support ladder jack scaffolds.  a) The extension ladder being used to support the ladder jack scaffold platform was not setup at a 4:1 angle.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B16

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 26, 2013
Abate by
Dec 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired:    a)  Employees were using an extension ladder which had damaged cleats.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B01

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 26, 2013
Abate by
Dec 9, 2013
Penalty
Initial $2,000 · Current $812 Reduced
29 CFR 1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a)  Employees were using two Werner alluminum extension ladders to gain access to the roof.  Both of which did not extend 3 feet above the upper landing being accessed.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $812.25
  • · Z (S) $2000

1926.1053 B05 I

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 26, 2013
Abate by
Dec 9, 2013
Penalty
Initial $2,000 · Current $812 Reduced
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders shall used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):  a)  The two extentsion ladders being used to access the roof were not set up a 4:1 angle.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $812.25
  • · Z (S) $2000

View SAC INC.'s full OSHA safety record →