MIAMI, FL ·
OSHA Inspection: ARMSTRONG POWER SYSTEMS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARMSTRONG POWER SYSTEMS, LLC in 5100 NW 72ND AVE, MIAMI, FL 33166 (NAICS 332322). OSHA activity number 339464703.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMSTRONG POWER SYSTEMS, LLC
- Site address
- 5100 NW 72ND AVE
- City
- MIAMI
- State
- FL
- ZIP
- 33166
- Mailing
- 5100 NW 72ND AVE, MIAMI, FL 33166
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 14
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.136 A
- Issued
- Jan 24, 2014
- Abate by
- Feb 12, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.136(a): The employer did not ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet are exposed to electrical hazards: On or about 11/2/2013, at the above addressed jobsite, employer did not ensure that employees were using adequate foot protection while engaged in welding of a steel tank, exposing them to a crush hazard. NOTE: CERTIFICATION OF ABATEMENT MUST BE PROVIDED FOR THIS ITEM.
Recent events (1)
- · Z (S) $1600
1910.254 D09 III
- Issued
- Jan 24, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replace: On or about 11/2/2013, at the above addressed jobsite, employees were engaged in welding work using cables with exposed bare conductors, exposing them to an electrical hazard.
Recent events (1)
- · Z (S) $1600
More inspections in this industry (NAICS 332322)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339464703.