OSHA Inspection: DESIGN DECORATORS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DESIGN DECORATORS in 3076 JASPER STREET, PHILADELPHIA, PA 19134 (NAICS 335129). OSHA activity number 339466765.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Design Decorators — free Get an email when a new federal OSHA severe-injury report for Design Decorators is published. One employer, no account, unsubscribe in one click.
Establishment
DESIGN DECORATORS
Site address
3076 JASPER STREET
City
PHILADELPHIA
State
PA
ZIP
19134
Mailing
3076 JASPER STREET, PHILADELPHIA, PA 19134
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335129
Employees
11
Ownership type
A

8 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 3 instances 4 exposed
Issued
Jan 10, 2014
Abate by
Jan 23, 2014
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    a) 3076 Jasper Street, garland machine area - The "X-Mas Tinsel making Machine" was not equipped with guards to protect employees from point of operation, ingoing nip points and rotating part hazards, while making garland.  Observed on or about November 5, 2013.    b) 3076 Jasper Street, fabrication area - The "Bateman" shear was not equipped with guards to protect employees from point of operation hazards while cutting steel rod.  Observed on or about November 5, 2013.    c) 3076 Jasper Street, drill area - The milling machine equipped with a drill attachment was not equipped with guards to protect employees from rotating part hazards, while making decorations.  Observed on or about November 5, 2013.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2800
  • — Z (S) $2800

1910.303 B07 I

Serious Gravity 5 2 instances 6 exposed
Issued
Jan 10, 2014
Abate by
Jan 23, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.    a) 3076 Jasper Street, Fuse Panel - Employees resetting breakers were not protected from electrocution hazards by effectively closing unused opening in the fuse panel.  Observed on or about November 5, 2013.    b) 3076 Jasper Street, Fuse Panel - Employees resetting breakers were not protected from electrocution hazards by effectively closing unused opening in the fuse panel.  Observed on or about December 4, 2013.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.305 B02 I

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 10, 2014
Abate by
Jan 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.    a) 3076 Jasper Street, time clock area - Employees punching in and out for the workday were exposed to electrical hazards from a flexible cord connected to a light without strain relief.  Observed on or about November 5, 2013.    b) 3076 Jasper Street, time clock area - Employees punching in and out for the workday were exposed to electrical hazards from a flexible cord connected to a light without strain relief.  Observed on or about December 4, 2013. 29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.  a) 3076 Jasper Street, Phase Changer Junction Box - The Phase Changer Junction Box did not have a faceplate exposing employees to an electrical hazard.  Observed on or about November 5, 2013.
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1910.37 A03

Other-than-serious 2 instances 6 exposed
Issued
Jan 10, 2014
Abate by
Jan 23, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed.    a) Exit door near rear of building - Exit routes were not kept free and unobstructed, exposing employees to fire hazards while working in the warehouse.  Observed on or about November 5, 2013.    b) Exit door near rear of building - Exit routes were not kept free and unobstructed, exposing employees to fire hazards while working in the warehouse.  Observed on or about December 4, 2013
Recent events (3)
  • — F (O) $0
  • — C (S) $2000
  • — Z (S) $2000

1910.303 G01

Serious Gravity 5 2 instances 6 exposed
Issued
Jan 10, 2014
Abate by
Jan 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  a) 3076 Jasper Street, Fuse Panel - Electrical service panel did not have sufficient access to permit ready and safe operation, exposing employees to electrical hazards.  Observed on or about November 5, 2013.  b) 3076 Jasper Street, Fuse Panel - Electrical service panel did not have sufficient access to permit ready and safe operation, exposing employees to electrical hazards.  Observed on or about December 4, 2013.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.37 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 10, 2014
Abate by
Jan 23, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.37(b)(1): 29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that employees with normal vision could see along the exit route.    a) 3076 Jasper Street, Rear exit - Employees were exposed to fire hazards from exit routes that were not adequately lit. Observed on or about November 5, 2013.
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1910.23 C01

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 10, 2014
Abate by
Jan 23, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toe boards.    a) 3076 Jasper Street, entrance ramp - Employees walking on an open-sided ramp were exposed to falls hazards of four (4) feet and greater without adequate fall protection or guard rails.  On or about November 5, 2013.    b) 3076 Jasper Street, entrance ramp - Employees walking on an open-sided ramp were exposed to falls hazards of four (4) feet and greater without adequate fall protection or guard rails.  On or about December 4, 2013.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.22 A01

Repeat Gravity 10 6 instances 6 exposed
Issued
Jan 10, 2014
Abate by
Jan 23, 2014
Penalty
Initial $5,600 · Current $200 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a) 3076 Jasper Street, sewing room - Employees making Christmas decorations were not protected from trip hazards while working in cluttered areas.  Observed on or about November 5, 2013.    b) 3076 Jasper Street, machine area - Employees making Christmas decorations were not protected from trip hazards while working in cluttered areas.  Observed on or about November 5, 2013.    c) 3076 Jasper Street, garland area - Employees making Christmas decorations were not protected from trip hazards while working in cluttered areas.  Observed on or about November 5, 2013.    d) 3076 Jasper Street, aisles - Employees making Christmas decorations were not protected from trip hazards while working in cluttered areas.  Observed on or about November 5, 2013.    e) 3076 Jasper Street, garland area - Employees making Christmas decorations were not protected from trip hazards while working in cluttered areas.  Observed on or about December 4, 2013.    f) 3076 Jasper Street, aisles - Employees making Christmas decorations were not protected from trip hazards while working in cluttered areas.  Observed on or about December 4, 2013.    Design Decorators, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1910.22(a)(1)), which was contained in OSHA inspection number 873263, citation number 1, item number 1 and was affirmed as a final order on (07/31/2013), with respect to a workplace located at 3076 Jasper Street, Philadelphia, PA.
Recent events (3)
  • — F (R) $200
  • — C (R) $5600
  • — Z (R) $5600

View Design Decorators's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339466765.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.