BUFFALO, NY ·
OSHA Inspection: GREG NIKIEL DBA LOOK AT THAT HOME IMPROVEMENT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GREG NIKIEL DBA LOOK AT THAT HOME IMPROVEMENT in 190 HOYT STREET, BUFFALO, NY 14213 (NAICS 238160). OSHA activity number 339473746.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREG NIKIEL DBA LOOK AT THAT HOME IMPROVEMENT
- Site address
- 190 HOYT STREET
- City
- BUFFALO
- State
- NY
- ZIP
- 14213
- Mailing
- 395 AMHERST STREET, BUFFALO, NY 14207
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.21 B02
- Issued
- Nov 21, 2013
- Abate by
- Feb 3, 2014
- Penalty
- Initial $2,000 · Current $500 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 11/06/13, on residential jobsite located at 190 Hoyt St., Buffalo, NY: Employees engaged in roofing work, using ladders, ladder jack scaffolds, electrical equipment such as saws, extension cords, air compressors, and air nailers were not trained about Osha fall protection regulations, scaffold regulations, ladder safety regulations, electrical regulations, personal protective equipment requirements, and applicable OSHA regulations pertaining to other hazards that the employees may potentially be exposed to when engaged in roofing work. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $500
- · Z (S) $2000
1926.95 A
- Issued
- Nov 21, 2013
- Abate by
- Dec 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) On or about 11/06/13, on roof of residential jobsite located at 190 Hoyt St., Buffalo, NY: Employees operating or working in areas where Pneumatic Nail Guns were being used were not wearing safety glasses and hardhats. b) On or about 11/06/13, on residential jobsite located at 190 Hoyt St., Buffalo, NY: Employees cleaning up old roofing materials on the ground were exposed to getting struck in the eyes/head by roofing material being dropped/thrown from the roof to the ground approx. 22 ft. above them. The employees were not wearing safety glasses and hardhats. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B11
- Issued
- Nov 21, 2013
- Penalty
- Initial $2,000 · Current $500 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 11/06/13, on residential jobsite located at 190 Hoyt St., Buffalo, NY: Employees engaged in roofing work on a steep roof were exposed to a fall of approx. 22 foot because no fall protection system was utilized. The roof pitch was estimated to be approx. 12 in 12. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $500
- · Z (S) $2000
1926.451 G01 I
- Issued
- Nov 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 11/06/13, on residential jobsite located at 190 Hoyt St., Buffalo, NY: Employees walking & working from a narrow aluminum "pic" of a ladder jack scaffold erected on the south side of the house were exposed to a fall of approx. 20 ft. to the ground. No personal fall arrest system or other fall protection system was utilized. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B01
- Issued
- Nov 21, 2013
- Penalty
- Initial $2,000 · Current $500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 11/06/13, on residential jobsite located at 190 Hoyt St., Buffalo, NY: Employees were exposed to a fall of approx. 20 ft. when an extension ladder was used to access the narrow aluminum "pic" of a ladder jack scaffold erected on the south side of the house. The siderails of the ladder extended approx. 18 inches above the "pic". NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $500
- · Z (S) $2000
1926.451 E01
- Issued
- Nov 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) On or about 11/06/13, on residential jobsite located at 190 Hoyt St., Buffalo, NY: Employees were exposed to a fall of approx. 22 ft. to the ground while hoisting themselves up a distance of approx. 3 ft. from the narrow aluminum "pic" of the ladder jack scaffold to the roof. Direct access to the roof was not provided. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339473746.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.