OSHA Inspection: HUTTIG BUILDING PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HUTTIG BUILDING PRODUCTS, INC. in 65 SPRING HILL ROAD, SACO, ME 04072 (NAICS 321911). OSHA activity number 339474454.

Watch Huttig Building Products, INC. — free Get an email when a new federal OSHA severe-injury report for Huttig Building Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
65 SPRING HILL ROAD
City
SACO
State
ME
ZIP
04072
Mailing
65 SPRING HILL ROAD, SACO, ME 04072
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
42
Ownership type
A

8 citations on file for this inspection.

1910.157 C01

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3300.00 · Current $3300.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Northwest Corner of Building - The fire extinguisher mounted at the exit was obstructed by a pallet of material.
Recent events (1)
  • — Z (S) $3300

1910.157 E02

Serious Gravity 1 1 instance 33 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  Establishment - The portable fire extinguishers received their last monthly inspection in August 2013.
Recent events (1)
  • — Z (S) $0

1910.213 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5500.00 · Current $5500.00
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock being cut to give the maximum protection possible for the operation being performed:  Interior Custom Area - The guard on the sides of the lower exposed portion of the Delta radial saw blade did not guard the full diameter of the blade.
Recent events (1)
  • — Z (S) $5500

1910.213 H04

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator:  a)  Interior Custom Area - The cutting head on the Delta radial saw did not return to the starting position when released by the operator.  b)  Exterior Prep Area - The cutting head on the Delta radial saw did not return to the starting position when released by the operator.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4400.00 · Current $4400.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  Interior Custom Area - Both work rests on the Porter Cable six inch bench grinder were greater than one eight of an inch from their respective grinding wheel.
Recent events (1)
  • — Z (S) $4400

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  Interior Custom Area, Porter Cable bench grinder - The distance between the two abrasive wheels and their respective adjustable tongue guards exceeded one fourth of an inch.
Recent events (1)
  • — Z (S) $0

1910.332 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  Establishment - An employee was not trained in and familiar with the selection, use, and inspection of the personal protective equipment necessary for protection against the hazards of electrical shock, arc flash, and arc blast when working on or near exposed energized parts greater than 50 volts, and when testing for the absence of voltage.
Recent events (1)
  • — Z (S) $7000

1910.335 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(1): Employees working in areas where there are potential electrical hazards were not provided with, and did not use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed:  Establishment - An employee exposed to the hazards of electrical shock and arc flash was not provided with, and did not use, electrical protective equipment appropriate for the specific parts of the body to be protected and for the work performed.