Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNIVERSAL STEEL SUPPLY, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of UNIVERSAL STEEL SUPPLY, INC. in 5005 AUGUSTA RD, GARDEN CITY, GA 31408 (NAICS 423390). OSHA activity number 339475089.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Universal Steel Supply, INC. — free Get an email when a new federal OSHA severe-injury report for Universal Steel Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5005 AUGUSTA RD
City
GARDEN CITY
State
GA
ZIP
31408
Mailing
P.O. BOX 7844, SAVANNAH, GA 31418
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423390
Employees
20
Ownership type
A

9 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 6 exposed
Issued
May 2, 2014
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:     A) North east warehouse exit door, on or about November 8, 2013, the exit route to the north east exit door was blocked by steel material, exposing employees to a hazard of receiving lacerations and or fractures to their legs.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.101 B

Serious Gravity 5 1 instance 6 exposed
Issued
May 2, 2014
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    A) Rear of warehouse, on or about November 8, 2013, an acetylene cylinder stored in an upright position was not secured to prevent it from being knocked over, exposing employees to a hazard of being struck by the cylinder.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.157 C01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
May 2, 2014
Abate by
May 29, 2014
Penalty
Initial $1,360 · Current $0 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  A) Center aisle of warehouse, on or about November 14, 2013, the fire extinguishers located down the center of the warehouse were blocked by steel plates and other steel material, exposing employees to abrasion and laceration hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1360

1910.179 N03 III B

Serious Gravity 10 1 instance 2 exposed
Issued
May 2, 2014
Abate by
May 29, 2014
Penalty
Initial $6,300 · Current $4,196 Reduced
29 CFR 1910.179(n)(3)(iii)(b): During movement, the load contacted obstructions:    A) Rear of warehouse, on or about November 7, 2013, an employee used an overhead crane with a below-the-hook lifting device (plate clamp) to move a steel plate that had other steel plates contacting (leaning against) the plate being move, exposing the employee to a hazard of being struck by falling plates.
Recent events (2)
  • — I (S) $4196
  • — Z (S) $6300

1910.212 A01

Serious Gravity 5 3 instances 4 exposed
Issued
May 2, 2014
Penalty
Initial $1,445 · Current $1,267 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    A)  Center aisle of warehouse, on or about November 8, 2013, the unused portion of the saw blade on a Hyd Mech vertical band saw was not guarded, exposing employees to a lacerations and amputation hazards.                  B)  Center aisle of warehouse, on or about November 8, 2013, the unused sections of the iron worker blade was not guarded to prevent employees from putting their fingers or hands into the area, exposing employees to a lacerations and amputation hazards.    C) Center front section of warehouse, on or about November 8, 2013, the rear area of a shearing machine was not guarded to prevent employees from entering the area during operation.
Recent events (2)
  • — I (S) $1267
  • — Z (S) $1445

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
May 2, 2014
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     A)    Center aisle of warehouse, on or about November 8, 2014, an electrical connection (relay) on the side of a Champion air compressor did not have a cover, exposing employees to an electrical shock/burn hazard.
Recent events (2)
  • — I (S) $1224
  • — Z (S) $2040

1910.305 D02

Serious Gravity 5 2 instances 3 exposed
Issued
May 2, 2014
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.305(d)(2): Panelboards mounted in cabinets, cutout boxes, or enclosures designed for the purpose were not dead front:     A)    Center aisle of warehouse, on or about November 8, 2013, two electrical breaker panels were not dead front and had an opening in the face plate, exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1910.305 B01 II

Serious Gravity 5 2 instances 4 exposed
Issued
May 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   A)   Center aisle of warehouse, on or about November 8, 2013, the electrical control boxes to an air compressor and an iron worker machine had unused opening in boxes, exposing employees to an electrical burns/shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 A03

Other-than-serious 1 instance 1 exposed
Issued
May 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.253(a)(3): Apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds used in an oxygen-fuel gas system had not been approved:   A)    North west area of warehouse, on or about November 8, 2014, the gauges on the oxygen regular did not have protective lens in place.