Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: NOLANDS CYLINDER HEAD SERVICES

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NOLANDS CYLINDER HEAD SERVICES in 159 CHARLOTTE ST, KANSAS CITY, MO 64108 (NAICS 336312). OSHA activity number 339479792.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nolands Cylinder Head Services for free Get an email when a new federal OSHA severe-injury report for Nolands Cylinder Head Services is published. One employer, no account, unsubscribe in one click.
Site address
159 CHARLOTTE ST
City
KANSAS CITY
State
MO
ZIP
64108
Mailing
159 CHARLOTTE ST, KANSAS CITY, MO 64108
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336312
Employees
8
Ownership type
Private (A)

8 citations on file for this inspection.

1910.22 D01

Other-than-serious 2 instances 2 exposed
Issued
Nov 20, 2013
Abate by
Dec 25, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.    (a) In the back room there were two raised overhead storage areas. The west storage area had the compressor on it. Employees were exposed to crushing hazards if the structures were to be overloaded and fail. The overhead storage areas were not posted with load ratings      (b) The east storage area had some heads, five gallon buckets, and boxes stored on it. Employees were exposed to crushing hazards if the structures were to be overloaded and fail. The overhead storage areas were not posted with load ratings.     Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2000

1910.23 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 20, 2013
Abate by
Dec 25, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not be equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:  (a) Stairs leading up to the storage area in the back room did not have standard stair railings in that there was no midrail. Employees were exposed to a fall hazard greater than four feet.  Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1910.147 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 20, 2013
Abate by
Dec 25, 2013
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) Where mechanical repair work is performed on hard wired equipment, no energy control procedure, training, periodic inspections, or specific procedures were developed or implemented. Equipment is not limited to, but includes two seat and guide machines, The Peterson with a floating table, bead blaster, valve facer, downdraft table, two jetwashers, glove spraywash cabinet, sonic cleaner, shot blaster, and metal lathe. Employees are exposed to potential unexpected release of energy and moving parts.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $2800

1910.212 A01

Deleted Serious Gravity 10 3 instances 8 exposed
Issued
Nov 20, 2013
Abate by
Dec 25, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Machine guarding was not provided in the following instances:      (1) The Rottler S680A, Serial Number 044, computerized seat and guide machine, did not have guarding to protect the operator from hazards created by the the spinning chuck, holder and blade.      (2) The Serdi 4.0 Power, Serial Number 453, manual seath and guide machine, did not have guarding to protect the operator from hazards created by the spinning chuck, holder and blade.      (3) The LeBlond metal lathe did not have guarding to protect the operator from hazards created by the point of operation and rotating parts.   Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1910.215 B09

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 20, 2013
Abate by
Dec 25, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) The Jet 8 inch Bench Grinder, SN 08112676, did not have a tongue guard to protect the operator from projectile pieces of stone if the stone were to break.    Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.242 B

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 20, 2013
Penalty
Initial $2,400 · Current $0 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a) In various locations throughout the production area, but not limited to the air gun found at the vacuum table, air guns were found to not be of the safety type and air pressure was not reduced to less than 30 p.s.i.. The air guns were used to dry the water off the heads and to remove debris after wire brusing ports. Employees were exposed to air injection hazards.  This violation was abated during inspection. Abatement certification for this violation is not required.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2400

1910.305 G01 IV

Serious Gravity 10 2 instances 8 exposed
Issued
Nov 20, 2013
Abate by
Dec 25, 2013
Penalty
Initial $2,800 · Current $1,200 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):     (a) Pressure Testing Area; The SPX Robinair Vacumaster vacuum pump and a florescent light fixture were plugged into an orange extension cord equipped with three receptacles. The flexible orange extension cord was used instead of fixed wiring. Employees were exposed to electrical hazards.     Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2800

1910.1200 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 20, 2013
Abate by
Dec 25, 2013
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following:    (a) There is no written hazard communication program. Ultrasonic 7 contains potassium hydroxide, causes severe burns and is used in the ultrasonic cleaner. ZEP Formula 15282 is a recirculating spray-washer product used in the washers that contains sodium metasilicate, a corrosive.     Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1600

View Nolands Cylinder Head Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339479792.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.