Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SNYDER DRILLING CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SNYDER DRILLING CORP. in RIG 8, R.S. TURNER LEASE, WELL 2, 15 MILES E. OF ANSON, ANSON, TX 79501 (NAICS 213112). OSHA activity number 339480287.

Watch Snyder Drilling Corp. — free Get an email when a new federal OSHA severe-injury report for Snyder Drilling Corp. is published. One employer, no account, unsubscribe in one click.
Site address
RIG 8, R.S. TURNER LEASE, WELL 2, 15 MILES E. OF ANSON
City
ANSON
State
TX
ZIP
79501
Mailing
P.O. BOX 2798, ALBANY, TX 76430
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
4
Ownership type
A

2 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:  On or about November 5, 2013, on the Rig #8, the employer did not provide standard railing or the equivalent that would protect employees from falling. Employees were exposed to a fall hazard of greater than four feet in the following instances:    a)    To the right and middle of the rig, one employee was observed standing on the platform next to the operator platform where no railing or the equivalent was provided.      b)    On the Reverse Unit truck, one employee was observed standing on the platform where no railing or the equivalent was provided.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.157 C04

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $340.00 · Current $204.00 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  On or about November 5, 2013, on the Rig #8, the single fire extinguisher (un-labeled) on the rig was not maintained in a fully charged and operable condition. Employees were exposed fire hazards.