FORT LAUDERDALE, FL —
OSHA Inspection: PARSONS TRANSPORTATION GROUP LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of PARSONS TRANSPORTATION GROUP LLC in 100 AIRPORT BLVD FORT LAUDERDALE HOLLYWOOD AIRPORT, FORT LAUDERDALE, FL 33315 (NAICS 237990). OSHA activity number 339480493.
Where did this inspection happen?
- Establishment
- PARSONS TRANSPORTATION GROUP LLC
- Site address
- 100 AIRPORT BLVD FORT LAUDERDALE HOLLYWOOD AIRPORT
- City
- FORT LAUDERDALE
- State
- FL
- ZIP
- 33315
- Mailing
- 1170 LEE WAGENER BOULEVARD SUITE 211, FORT LAUDERDALE, FL 33315
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237990
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.701 A
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.701(a): Construction loads were placed on a concrete structure or portion of a concrete structure without the employer having determined, based on information received from a person who was qualified in structural design, that the structure or portion of the structure is capable of supporting the loads: On or about 11/02/2013, at the Fort Lauderdale Airport Runway Expansion, a 12-inch water main was placed on un-braced concrete beams without ensuring that the beams could resist the lateral load from the weight of the water main. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1926.704 A
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.704(a): Precast concrete wall units, structural framing and tilt-up wall panels were not adequately supported to prevent overturning and to prevent collapse until permanent connections were completed: On or about 11/02/2013, at the Fort Lauderdale Airport Runway Expansion Project, pre-cast concrete beams were not braced and were set on bearing plates the did not have retainers installed to prevent movement of the beams. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
More inspections in this industry (NAICS 237990)
HARTFORD CITY, IN—2026-07-10
WHITE CONSTRUCTION
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SAN LEANDRO, CA—2026-07-07
SHIMMICK CONSTRUCTION COMPANY, INC
FIRCREST, WA—2026-07-07
WA317991974 - CONTINENTAL DIRT CONTRACTORS
STEVENSVILLE, MD—2026-07-07
KOKOSING INDUSTRIAL, INC.
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339480493.