OSHA Inspection: SORIN GROUP USA, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SORIN GROUP USA, INC. in 14401 W. 65TH WAY, ARVADA, CO 80004 (NAICS 339112). OSHA activity number 339481756.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sorin Group USA, INC. — free Get an email when a new federal OSHA severe-injury report for Sorin Group USA, INC. is published. One employer, no account, unsubscribe in one click.
Site address
14401 W. 65TH WAY
City
ARVADA
State
CO
ZIP
80004
Mailing
14401 W. 65TH WAY, ARVADA, CO 80004
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339112
Employees
250
Ownership type
A

3 citations on file for this inspection.

1910.23 C01

Other-than-serious 1 instance 4 exposed
Issued
Mar 14, 2014
Penalty
Initial $1,913 · Current $1,913
29 CFR 1910.23(c)(1):  Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    a)  On or about November 12, 2013, and at times prior, employees were exposed to fall hazards of greater than 4 feet when they worked in the storage area above the maintenance office because the mezzanine level floor was not equipped with standard railings on all sides.
Recent events (2)
  • — I (O) $1913
  • — Z (S) $1913

1910.1052 D02

Other-than-serious 1 instance 3 exposed
Issued
Mar 14, 2014
Penalty
Initial $2,250 · Current $2,250
29 CFR 1910.1052(d)(2):  The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride:       a)  On or about November 12, 2013, and at times prior, employees were exposed to unknown concentrations of methylene chloride because the employer failed to conduct an initial exposure assessment for employees of the Ortho fuser line that used a solvent mixture, which contained 50% methylene chloride, as an adhesive for assembly of medical parts.
Recent events (2)
  • — I (O) $2250
  • — Z (S) $2250

1910.305 G01 IV

Other-than-serious 3 instances 15 exposed
Issued
Mar 14, 2014
Abate by
Mar 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv):  Flexibles cords and cables were used for purposes prohibited by subparagraphs (a) through (e) of this paragraph:     a)  On or about November 12, 2013, and at times prior, employees were exposed to electrical shock and fire hazards because flexible cords were attached to building surfaces and used as a substitute for fixed wiring (such as conduit) in the maintenance shop and the CVE room.  Flexible cords were attached to the wall in the maintenance shop and attached to the ceiling and direct wired into standard metal outlet boxes in the CVE room.