Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: RED DIAMOND ENERGY SERVICES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RED DIAMOND ENERGY SERVICES INC. in WEST FLOWER UNIT LEASE, WELL #74, RIG #9, ASPERMONT, TX 79502 (NAICS 213112). OSHA activity number 339481814.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RED Diamond Energy Services INC. for free Get an email when a new federal OSHA severe-injury report for RED Diamond Energy Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
WEST FLOWER UNIT LEASE, WELL #74, RIG #9
City
ASPERMONT
State
TX
ZIP
79502
Mailing
710 NW AVE. D P.O. BOX 7269, HAMLIN, TX 79520
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
4
Ownership type
Private (A)

2 citations on file for this inspection.

1910.23 D01

Serious Gravity 1 1 instance 4 exposed
Issued
Feb 11, 2014
Abate by
Mar 21, 2014
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:    Rig #9: On or about November 5, 2013, one employee was observed walking down the stair case located on the operator's side, the stairs were missing rails both sides. This condition exposed the employees to a trip hazard.
Recent events (2)
  • · I (S) $1607
  • · Z (S) $2295

1910.157 C04

Other-than-serious 1 instance 4 exposed
Issued
Feb 11, 2014
Abate by
Feb 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  Rig #9: On or about November 5, 2013, the employer did not maintain in operating condition the fire extinguisher located on top of the battery box behind the cab. This condition exposed the employees to fire hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View RED Diamond Energy Services INC.'s full OSHA safety record →