ABILENE, TX —
OSHA Inspection: L. E. DELEKTA, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of L. E. DELEKTA, INC in 3226 S. CLACK RD, ABILENE, TX 79606 (NAICS 236210). OSHA activity number 339482275.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- L. E. DELEKTA, INC
- Site address
- 3226 S. CLACK RD
- City
- ABILENE
- State
- TX
- ZIP
- 79606
- Mailing
- 600 S. MACARTHUR #2412, COPPELL, TX 75019
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236210
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Apr 16, 2014
- Abate by
- May 5, 2014
- Penalty
- Initial $1,800 · Current $1,800
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: Construction Site: On or about November 07, 2013 the employer did not provide a stairway, ladder, ramp, or other safe means of egress located in a trench excavation more than 4 feet in depth and more than 25 feet of lateral travel. This condition exposed employees to a fall and/or crushed-by hazard from the excavation.
Recent events (1)
- — Z (S) $1800
1926.652 A01
- Issued
- Apr 16, 2014
- Abate by
- May 5, 2014
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): Construction Site: On or about November 07, 2013 the employer did not protect employees in an excavation from cave-ins by an adequate protective system that was more than five feet in depth that had no protective system. This condition exposed employees to crushed-by hazards from the excavation.
Recent events (1)
- — Z (S) $2520
More inspections at L. E. Delekta, INC
View L. E. Delekta, INC's full OSHA safety record →
More inspections in this industry (NAICS 236210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339482275.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.