OSHA Inspection: ENGINEERED PLASTIC COMPONENTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ENGINEERED PLASTIC COMPONENTS, INC. in 300 SHELLHOUSE DR., RANTOUL, IL 61866 (NAICS 326121). OSHA activity number 339483083.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Engineered Plastic Components, INC. for free Get an email when a new federal OSHA severe-injury report for Engineered Plastic Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
300 SHELLHOUSE DR.
City
RANTOUL
State
IL
ZIP
61866
Mailing
300 SHELLHOUSE DR., RANTOUL, IL 61866
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326121
Employees
261
Ownership type
Private (A)

10 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 20, 2013
Penalty
Initial $4,000 · Current $1,000 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:     Employees were exposed to trip and fall hazards while exiting the facility in the event of an emergency because the access to the side exit door was restrictd to 23 inches due to the placement of a storage cabinet.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $4000

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Dec 20, 2013
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:     Employees were exposed to smoke inhalation and burns because a fire extinguisher was not mounted and was sitting on the ground near an aisleway and was not identified.
Recent events (2)
  • · I (O) $0
  • · Z (S) $4000

1910.157 E03

Other-than-serious 1 instance 3 exposed
Issued
Dec 20, 2013
Abate by
Feb 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:      Employees were exposed to smoke inhalation and burns because a fire extinguisher had not received an annual maintenance check.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.303 B01 III

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 20, 2013
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.303(b)(1)(iii): Electrical insulation did not provide the mechanical strength and durability required to protect the electrical conductors:     Employees were exposed to electrical shock and burns because the conductor wires entering the panel box were not protected from abrasion because the sealtite insulation was pulled down.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $4000

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 20, 2013
Abate by
Jan 3, 2014
Penalty
Initial $4,000 · Current $3,000 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:          Employees were exposed to electrical hazards when using the suspended metal four gang box electrical outlet to plug in a fan because the unmounted receptacle box was not mounted according to the listed and labeling instructions.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $4000

1910.305 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 20, 2013
Abate by
Jan 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:   Employees were exposed to electrical shock and burns because the conductor wires entering the electrical box had a bushing that was pulled away from the opening and did not protect the cord from abrasion.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.332 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 20, 2013
Abate by
Feb 14, 2014
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.332(b)(1):  Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments:      Employees were exposed to contact with parts of fixed electric equipment and circuits while performing diagnostic testing on presses and electrical panel boxes, and the employees were not trained and familiar with the safety-related work practices.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.333 B02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(i):  The employer did not maintain a copy of the written procedures outlined in 29 CFR 1910.333 (b)(2) and did not make it available for inspection by employees:    Employees were exposed to contact with parts of fixed electric equipment and circuits while performing diagnostic testing on presses and electrical panel boxes, and the employer did not develop and maintain a copy of written electrical procedures that outlined how these activities would be conducted in order to maintain employee safety.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.333 B02 II A

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 20, 2013
Abate by
Feb 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(ii)(A): Safe procedures for deenergizing circuits and equipment were not determined before circuits or equipment were deenergized:        Employees were exposed to contact with parts of fixed electric equipment and circuits while performing diagnostic testing on presses and electrical panel boxes, and the employer did not determine safe procedures for deenergizing circuits.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1904.40 A

Deleted Other-than-serious 1 instance 10 exposed
Issued
Dec 20, 2013
Abate by
Jan 3, 2014
Penalty
Initial $1,000 · Current $0 Reduced
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours:   On November 13, 2013, injury and illness records for the Engineered Plastic Components facility, Rantoul IL, were requested for years 2010 through 2013 year-to-date, and copies of the records were not provided to the OSHA Compliance Officer within four (4) business hours.
Recent events (2)
  • · I (O) $0
  • · Z (O) $1000

View Engineered Plastic Components, INC.'s full OSHA safety record →