KANSAS CITY, MO ·
OSHA Inspection: PEREZ FOOD PRODUCTS INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PEREZ FOOD PRODUCTS INC in 2826 SOUTHWEST BLVD, KANSAS CITY, MO 64108 (NAICS 311991). OSHA activity number 339483521.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEREZ FOOD PRODUCTS INC
- Site address
- 2826 SOUTHWEST BLVD
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64108
- Mailing
- 2826 SOUTHWEST BLVD, KANSAS CITY, MO 64108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311991
- Employees
- 8
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Nov 19, 2013
- Abate by
- Dec 22, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) The two wrappers and the oven are hard-wired pieces of equipment that are maintained and repaired by employees. There is no energy control procedure, training, periodic inspections, lockout tagout hardware, or equipment specific procedures for locking out and tagging out equipment where the unexpected startup or release of stored energy could occur and cause injury. Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1960
- · Z (S) $2800
1910.219 C04 I
- Issued
- Nov 19, 2013
- Abate by
- Dec 22, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) Near the outfeed side of the oven, adjacent to the main aisle, the end door panel of the oven had been removed, exposing employees to three rotating projecting shafts. Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1960
- · Z (S) $2800
1910.303 B02
- Issued
- Nov 19, 2013
- Abate by
- Dec 22, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Downstream of the grinder, adjacent to where the masa comes out by conveyor, a metal junction box with prepunched knockouts intact, was being used as a pendent fourplex receptacle. Employees were exposed to electrical hazards. Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
1910.1200 E01
- Issued
- Nov 19, 2013
- Abate by
- Dec 22, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) The facility uses hazardous chemicals such as Zep Amine A, a disinfectant/sanitizer, without having developed, implemented or maintaining a written hazard communication program at the workplace. Zep Amine A can cause central nervous system depresion, burns to the eyes and skin, respiratory tract irritation, and chronic exposure can dammage the middle ear. Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
More inspections at Perez Food Products INC
View Perez Food Products INC's full OSHA safety record →
More inspections in this industry (NAICS 311991)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339483521.