ANDERSON, MO —
OSHA Inspection: MID TEC INC.*
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MID TEC INC.* in 2274 S. BUSINES HWY 71, ANDERSON, MO 64831 (NAICS 236210). OSHA activity number 339484909.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MID TEC INC.*
- Site address
- 2274 S. BUSINES HWY 71
- City
- ANDERSON
- State
- MO
- ZIP
- 64831
- Mailing
- 2274 S. BUSINES HWY 71, ANDERSON, MO 64831
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236210
- Employees
- 58
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.22 D01
- Issued
- Dec 12, 2013
- Abate by
- Jan 9, 2014
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. (a) The floor load for the mezzanine above the shop used for storage did not have the floor loading posted. The employer has provided proof of abatement.
Recent events (2)
- — I (S) $2100
- — Z (S) $2100
1910.147 C04 I
- Issued
- Dec 12, 2013
- Abate by
- Jan 31, 2014
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) In the south west part of the west shop, the Jaws V Iron Worker did not have a machine specific lockout/tagout procedure developed for energy control program. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.305 B02 I
- Issued
- Dec 12, 2013
- Abate by
- Jan 9, 2014
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) In the northwest corner of the shop, the box cover for the start switch was not in place, exposing employees to a 220 volt shock hazard. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
- — I (S) $0
- — Z (S) $2380
More inspections at MID TEC INC.*
View MID TEC INC.*'s full OSHA safety record →
More inspections in this industry (NAICS 236210)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339484909.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.