JACKSONVILLE, FL ·
OSHA Inspection: EL TRONO CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EL TRONO CONSTRUCTION, LLC in 11453 JOHNSON CREEK CIRCLE - LOT 131, JACKSONVILLE, FL 32208 (NAICS 238170). OSHA activity number 339485880.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EL TRONO CONSTRUCTION, LLC
- Site address
- 11453 JOHNSON CREEK CIRCLE - LOT 131
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32208
- Mailing
- 4839 CLARCONA ROAD APT 1, ORLANDO, FL 32810
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01 I
- Issued
- Dec 9, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: a. On or about November 13, 2013, the right side scaffold system was not fully planked on the first level and had gaps, exposing the employee to a 7.5 feet fall hazard. Abatement Certification and Documentation are not required
Recent events (1)
- · Z (S) $2400
1926.451 C02
- Issued
- Dec 9, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about November 13, 2013, both two buck high scaffold systems were erected in the dirt, exposing the employees to crushing hazards. The legs and posts were not erected with mudsills or base plates. Abatement Certification and Documentation are not required
Recent events (1)
- · Z (S) $2800
1926.451 E01
- Issued
- Dec 9, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a. On or about November 13, 2013, right side of the home, the two buck high scaffold system did not have a ladder. The employee climbed the rungs, exposing himself to a 7.5 feet fall hazard. b. On or about November 13, 2013, left side of the home, the two buck high scaffold system did not have a ladder. The employee climbed the rungs, exposing himself to a 9.5 feet fall hazard. Abatement Certification and Documentation are not required
Recent events (1)
- · Z (S) $2000
1926.451 F07
- Issued
- Dec 9, 2013
- Abate by
- Jan 6, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a. On or about November 13, 2013, both two buck high scaffold systems were not erected, moved or dismantled under the supervision of a competent person. Abatement Certification and Documentation are required
Recent events (1)
- · Z (S) $2800
1926.501 B13
- Issued
- Dec 9, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On or about November 13, 2013, roof area, the employee standing on the roof plastering the exterior of a two-story home was not protected from falling 9.5 feet by the use of a guardrail system, safety net system or a personal fall arrest system. Abatement Certification and Documentation are not required
Recent events (1)
- · Z (S) $2800