ANTIGO, WI ·
OSHA Inspection: AMRON
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMRON in 920 AMRON AVE, ANTIGO, WI 54409 (NAICS 332992). OSHA activity number 339486607.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMRON
- Site address
- 920 AMRON AVE
- City
- ANTIGO
- State
- WI
- ZIP
- 54409
- Mailing
- 920 AMRON AVE, ANTIGO, WI 54409
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332992
- Employees
- 209
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Feb 19, 2014
- Abate by
- Mar 28, 2014
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specify procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a) On or about October 15, 2013, specific procedural energy control steps were not developed and utilized to ensure employees performing energy control procedures were protected from hazardous energy sources. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- · I (S) $4410
- · Z (S) $6300
1910.147 D05 I
- Issued
- Feb 19, 2014
- Abate by
- Mar 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a) On or about October 15, 2013, a maintenance mechanic A did not relieve stored energy that had been trapped between the main steam line valve and the 25 mm line steam valve causing scalding water and steam to be released when the valve seal was broken by the employee. Abatement Certification and Abatement Documentation Required.