OSHA Inspection: ELTEQ MANAGEMENT COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ELTEQ MANAGEMENT COMPANY, INC. in 140 TWO CHATHAM CENTER, PITTSBURGH, PA 15219 (NAICS 561210). OSHA activity number 339487498.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elteq Management Company, INC. for free Get an email when a new federal OSHA severe-injury report for Elteq Management Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
140 TWO CHATHAM CENTER
City
PITTSBURGH
State
PA
ZIP
15219
Mailing
140 TWO CHATHAM CENTER, PITTSBURGH, PA 15219
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
55
Ownership type
A

11 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 4, 2014
Abate by
Apr 30, 2014
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:      a) Jobsite, Chatham Building # 1 roof, Pittsburgh, PA: On or about October 21, 2013, during maintenance activities on the roof, the employer did not ensure that appropriate fall protection systems/devices were used where fall hazards of up to approximately 100 feet were present. The employer had parapet wall, determined to be approximately 24-32 inches in height, around the perimeter of roof of the building, and harnesses, guardrails, safety nets or other fall protection was not in use while employees performed their work.     b. Jobsite, Chatham Building # 1 roof, Pittsburgh, PA: On or about November 6, 2013, during maintenance activities on the cooling tower, the employer did not ensure that fall protection systems/devices were used where employees were exposed to fall hazards of up to approximately 20 feet. Employees climbed up on top of these units and did not have guardrails, harnesses, safety nets or other fall protection in use while they performed their work.
Recent events (2)
  • · I (S) $2625
  • · Z (S) $3500

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 4, 2014
Abate by
Apr 1, 2014
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was isolated from the energy source and rendered inoperative:      a) Jobsite, Chatham Building # 1, Pittsburgh, PA: On or about October 15, 2013, during preventiive maintenance work on the chilling pumps for floor numbers 13-15, the employer did not ensure that a lockout/tagout program was in place to prevent the accidental start up of machinery while servicing and maintaining this equipment.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

1910.332 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 4, 2014
Abate by
Feb 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments:   a) Jobsite, Engine Room # 2, Pittsburgh, PA: On or about November 21, 2013, the employer did not ensure that employees were trained in electrical safety related workpractices in that employees were permitted to open electrical panel covers and place parts of their body near live energized, unguarded electrical components, exposing them to electrical shock hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2014
Abate by
Feb 14, 2014
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.219(d)(1): Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section:      a) Jobsite, Engine Room # 2, Pittsburgh, PA: On or about November 21, 2013, during maintenance activities, the employer did not ensure that the Quincy Air compressor unit, serial number 187361-1, had a guard over the rear section of the belt/pulley system, exposing employees to caught in and/or struck by hazards.     b) Jobsite, Engine Room # 2, Pittsburgh, PA: On or about November 21, 2013, during maintenance activities, the employer did not ensure that the Quincy Air Compressor unit, serial number 187362-1, had a guard over the rear section of the belt/pulley system, exposing employees to caught in and/or struck by hazards.     c) Jobsite, Engine Room # 1, Pittsburgh, PA: On or about November 21, 2013, during maintenance activities, the employer did not ensure that the DeVibliss Air Compressor Unit, serial number D4521, had guards over the rear section of the belt/pulley system, exposing employees to caught in and/or struck by hazards.
Recent events (2)
  • · I (S) $2625
  • · Z (S) $3500

1910.219 E01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2014
Abate by
Feb 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts were seven (7) feet or less from the floor level, the guard did extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt were 42 inches or less from the floor, the belt was not fully enclosed in accordance with paragraphs (m) and (o) of this section:   a) Jobsite, Engine Room # 2, Pittsburgh, PA: On or about November 21, 2013, during maintenance activities, the employer did not ensure that the Quincy Air compressor unit, serial number 187361-1, had a guard over the rear section of the belt/pulley system, exposing employees to caught in and/or struck by hazards.   b) Jobsite, Engine Room # 2, Pittsburgh, PA: On or about November 21, 2013, during maintenance activities, the employer did not ensure that the Quincy Air Compressor unit, serial number 187362-1, had a guard over the rear section of the belt/pulley system, exposing employees to caught in and/or struck by hazards.   c) Jobsite, Engine Room # 1, Pittsburgh, PA: On or about November 21, 2013, during maintenance activities, the employer did not ensure that the DeVibliss Air Compressor Unit, serial number D4521, had guards over the rear section of the belt/pulley system, exposing employees to caught in and/or struck by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 4, 2014
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a) Jobsite, Chatham # 3 boiler room, Pittsburgh, PA: On or about November 14, 2013, the employer did not ensure that unused openings in electrical boxes for the temporary wiring to the new boiler tank were effectively closed.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $2100

1910.22 A02

Other-than-serious 1 instance 1 exposed
Issued
Feb 4, 2014
Abate by
Feb 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2): The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition:   a) Jobsite, Engine Room # 2, Pittsburgh, PA: On or about November 21, 2013, floors were not kept dry in that water accumulations existed around equipment, exposing employees to slip/fall hazards.   b) Jobsite, Constant Pressure room, Pittsburgh, PA: On or about November 21, 2013, floors were not kept dry in that water accumulations existed around equipment, exposing employees to slip/fall hazards.    c) Jobsite, Engine Room # 1, Pittsburgh, PA: On or about November 21, 2013, floors were not kept dry in that water accumulations existed around equipment, exposing employees to slip/fall hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Feb 4, 2014
Abate by
Feb 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years:  a) Jobsite, Loading Dock area, Pittsburgh, PA: On or about November December 6, 2013, the employer did not ensure that forklift operators were appropriately evaluated to ensure that safe protocols were being followed and that compliance with the requirement of this standard were being met.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Feb 4, 2014
Abate by
Feb 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:   a) Jobsite, Engine Room # 1, Pittsburgh, PA: On or about November 21, 2013, the employer did not ensure that electrical equipment was properly used in that a wire mold junction box, with knockout panels on the sides, was attached to an electric power cord that dropped down from a reel system overhead.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B07

Other-than-serious 1 instance 1 exposed
Issued
Feb 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner:  Instances including but not limited to the following:  a) Jobsite, Engine Room # 1, Pittsburgh, PA: On or about November 21, 2013, the employer did not ensure that electrical equipment was installed in an appropriate fashion in that the ICC Panel OLC did not have the inner face secured due to loose or missing screws and the cover could not be closed due to damaged and/or missing securement hardware.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Feb 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws:   a) Jobsite, Engine Room #1, Pittsburgh, PA: On or about November 21, 2013, the employer did not ensure that strain relief was maintained on an electrical cord for a pipe threading machine.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Elteq Management Company, INC.'s full OSHA safety record →