OSHA Inspection: BROTHERS ELECTRICAL CONTRACTORS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BROTHERS ELECTRICAL CONTRACTORS in 1737 SUMNEYTOWN PIKE, KULPSVILLE, PA 19443 (NAICS 238210). OSHA activity number 339490112.

Watch Brothers Electrical Contractors — free Get an email when a new federal OSHA severe-injury report for Brothers Electrical Contractors is published. One employer, no account, unsubscribe in one click.
Site address
1737 SUMNEYTOWN PIKE
City
KULPSVILLE
State
PA
ZIP
19443
Mailing
1000 SUSSEX BLVD., BROOMALL, PA 19008
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
11
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3251.00 · Current $2276.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck by hazards from the improper use of an aerial lift:   a) Work Site - on or about October 31, 2013, employees were lifting a light post while it was suspended from the work platform of a Versalift Model VST 3600-1 Truck Mounted Aerial Lift which was not rated for lifting slung loads.   ABATEMENT NOTE: One feasible means of abatement is to employ the use of material handling equipment designed with the intent to hoist and place loads. This violation finds the aerial lift was employed in a manner not permitted by the Versalift Operator's Manual as the aerial lift was not rated for the lifting of overhanging loads. ANSI A92.5-1980, American National Standard for Boom-Supported Elevating Work Platform Section 13.2.
Recent events (2)
  • — I (S) $2275.7
  • — Z (S) $3251

1926.251 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2601.00 · Current $1821.00 Reduced
29 CFR 1926.251(a)(1): Defective rigging equipment was not removed from service.  a) Work site - on or about October 31, 2013, a light post was being raised using a single leg nylon sling that was significantly frayed and cut to the point of being defective per manufacturers guidelines.
Recent events (2)
  • — I (S) $1820.7
  • — Z (S) $2601

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3251.00 · Current $2276.00 Reduced
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift.  a) South side of project on Sumneytown Pike - On or about October 31, 2013, an employee was working from a vehicle mounted aerial lift, at a working height in excess of 14 feet above grade, without a body belt/personal fall arrest harness with an attached lanyard being worn and attached to the boom or basket.
Recent events (2)
  • — I (S) $2275.7
  • — Z (S) $3251

View BROTHERS ELECTRICAL CONTRACTORS's full OSHA safety record →