Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STONEWALLS BY GEORGE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STONEWALLS BY GEORGE, LLC in 46 WEST STREET, LITCHFIELD, CT 06759 (NAICS 238140). OSHA activity number 339490245.

Watch Stonewalls BY George, LLC — free Get an email when a new federal OSHA severe-injury report for Stonewalls BY George, LLC is published. One employer, no account, unsubscribe in one click.
Site address
46 WEST STREET
City
LITCHFIELD
State
CT
ZIP
06759
Mailing
23 SANDSTROM ROAD, NEW PRESTON, CT 06777
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.451 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed  according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide.  On or about 10/25/2013 at the 46 West Street Project, employees were using a tubular welded frame scaffolding system that was not tied or braced at the 4:1 height.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 E05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection:  On or about 10/25/2013 at the 46 West Street Project, employees were exposed to 30 foot fall hazards while using a walkway to access the roof deck from the tubular welded frame scaffold and no fall protection system was in use.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  On or about 10/25/2013 at the 46 West Street Project, the employer did not have a competent person supervise and provide direction on the installation and use of a tubular welded frame scaffold system.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339490245.