ROCKLAND, MA ·
OSHA Inspection: A.A. LAMONICA CONSTRUCTION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of A.A. LAMONICA CONSTRUCTION, INC. in 333 WEYMOUTH STREET, ROCKLAND, MA 02370 (NAICS 238160). OSHA activity number 339491276.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.A. LAMONICA CONSTRUCTION, INC.
- Site address
- 333 WEYMOUTH STREET
- City
- ROCKLAND
- State
- MA
- ZIP
- 02370
- Mailing
- 23 ELCOTT ROAD, QUINCY, MA 02169
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.404 F06
- Issued
- Nov 26, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Location: Jobsite Employees were exposed to electric shock while using an extension cord plugged into a drill, where the grounding wire was exposed and cut.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1926.405 G02 IV
- Issued
- Nov 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: Location: Jobsite Employees were exposed to electric shock while using a drill with exposed wires at the power cord plug, where the cord was not connected to a device or fitting so that strain relief was provided to prevent pull directly to joints or terminal screws.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B10
- Issued
- Nov 26, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. Location: Jobsite Employees were exposed to fall hazards in excess of 6 feet from the warehouse roof to the ground below, while working where fall protection had not been used or provided.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
More inspections at A.A. Lamonica Construction, INC.
View A.A. Lamonica Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339491276.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.