SYRACUSE, NY —
OSHA Inspection: KINANECO PRINTING SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KINANECO PRINTING SYSTEMS, INC. in 2925 MILTON AVE., SYRACUSE, NY 13209 (NAICS 323110). OSHA activity number 339492019.
Where did this inspection happen?
- Establishment
- KINANECO PRINTING SYSTEMS, INC.
- Site address
- 2925 MILTON AVE.
- City
- SYRACUSE
- State
- NY
- ZIP
- 13209
- Mailing
- 2925 MILTON AVE., SYRACUSE, NY 13209
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323110
- Employees
- 13
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $612.00 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) At the establishment, on or about 11/20/13: Annual training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting, in that the last training conducted was 2/23/10. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $816.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Bindery, on or about 11/20/13: Point of operation on an ISP Interlaken side stitcher, ISP Interlaken saddle stitcher and a Challenge EH-3C three head paper drill machine were not guarded. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $816
- — Z (S) $1360
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $612.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Mechanical Room, on or about 11/20/13: Two circuit breaker panels each had one blank missing exposing live electrical parts. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.147 C07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer had not certified that employee training for the lockout/tagout program had been accomplished and kept up to date: a) At the establishment, on or about11/20/13: There was no documentation that training of affected employees had been accomplished on the lockout/tagout program. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) At the establishment, on or about 11/20/13: Operators of powered industrial trucks were last evaluated January, 2010. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Large Format Dept., on or about 11/20/13: Extension cords providing current to two air compressors and a pump for a FB910 ink jet printer were strung along the floor and overhead and being used as permanent wiring. b) Karat Room, on or about 11/20/13: An extension cord with a plug adapter attached providing current to fluorescent light fixtures were tie wrapped along the wall and being used as permanent wiring. Abatement certification must be submitted for these items.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 323110)
MINNEAPOLIS, MN—2026-05-20
111284 - MARTH GROUP LLC DBA ENPOINTE
GLENDALE, KY—2026-02-04
68801 - PG-GERALD LLC
PORTLAND, OR—2026-01-16
317742947 - PEP PRINTING INC
MINNEAPOLIS, MN—2025-11-18
110299 - OMEGA LITHOGRAPH INC
BELLINGHAM, WA—2025-09-05
WA317987718 - CAPITOL CITY PRESS INC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339492019.