BENSALEM, PA ·
OSHA Inspection: TC MILLWORK, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TC MILLWORK, INC. in 3433 MARSHALL LANE, BENSALEM, PA 19020 (NAICS 321918). OSHA activity number 339492381.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TC MILLWORK, INC.
- Site address
- 3433 MARSHALL LANE
- City
- BENSALEM
- State
- PA
- ZIP
- 19020
- Mailing
- 3433 MARSHALL LANE, BENSALEM, PA 19020
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 88
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.101 B
- Issued
- Dec 31, 2013
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) Maintenance Work Shop Area -- On or about Nov 19, 2013, an employee was observed performing a job task around ten unsecured compressed gas cylinders, exposing employees to a struck-by hazard if the cylinders are tipped over. ABATEMENT NOTE: cylinders must be properly supported to prevent it from being knocked over while in storage or during use. (Compressed Gas Association Pamphlet P-1-1965 para 3.4.4)
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.147 C06 II
- Issued
- Dec 31, 2013
- Abate by
- Feb 3, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The certification did not identify the machine or equipment on which the energy control procedure was being utilized:
Recent events (2)
- · I (O) $1750
- · Z (S) $3500
More inspections at TC Millwork, INC.
View TC Millwork, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339492381.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.