On , OSHA opened a complaint safety inspection of M-1 SUPPORT SERVICES in 525 QUENTIN ROSEVELT HANGER 525, SAN DIEGO, CA 92135 (NAICS 336411). OSHA activity number 339492589.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M-1 Support Services for free Get an email when a new federal OSHA severe-injury report for M-1 Support Services is published. One employer, no account, unsubscribe in one click.
Site address
525 QUENTIN ROSEVELT HANGER 525
City
SAN DIEGO
State
CA
ZIP
92135
Mailing
300 N ELM ST STE 101, DENTON, TX 76201
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336411
Employees
12
Ownership type
Private (A)

3 citations on file for this inspection.

1910.243 B02

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 21, 2014
Abate by
Feb 4, 2014
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected.    The employer did not ensure that air hose used for pneumatic tools connected to air manifold at prep area near support beam 18 was repaired accordingly to manufactures recommendations. The attached air hose fitting was secured by a worm-driven water hose clamp which was not designed for high pressure compressed hose usage, thereby exposing the employees struck-by hazards associated to hose whipping action.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3000

1910.303 B02

Other-than-serious 1 instance 6 exposed
Issued
Jan 21, 2014
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    The employer did not ensure electrical equipment is used or installed in accordance with the listing or labeling instructions, where a surge protector was used to provide power to applinces such as microwave and refrigerator used by employees in the office.
Recent events (2)
  • · I (O) $1500
  • · Z (S) $3000

1910.305 B01 II

Other-than-serious 1 instance 6 exposed
Issued
Jan 21, 2014
Abate by
Feb 4, 2014
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about 19 November 2013, the employer did not insure that knockout openings not in use on an energized junction box mounted near workstation support beam 18 was effectively closed, exposing employees to electrical shock hazards.
Recent events (2)
  • · I (O) $1500
  • · Z (S) $3000

View M-1 Support Services's full OSHA safety record →