NEW LENOX, IL —
OSHA Inspection: COMCAST OF ILLINOIS VI, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of COMCAST OF ILLINOIS VI, INC. in E. LARAWAY RD & RACHEL RIDGE DR., NEW LENOX, IL 60451 (NAICS 515210). OSHA activity number 339492712.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMCAST OF ILLINOIS VI, INC.
- Site address
- E. LARAWAY RD & RACHEL RIDGE DR.
- City
- NEW LENOX
- State
- IL
- ZIP
- 60451
- Mailing
- 8101 W. 183RD ST., TINLEY PARK, IL 60487
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 515210
- Employees
- 144
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 C02
- Issued
- Dec 5, 2013
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. a. On or about November 18, 2013 - at the above addressed jobsite, employees working inside the eight (8) foot deep trench were not provided with a safe means of egress.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1926.651 K01
- Issued
- Dec 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated. a. On or about November 18, 2013 - at the above addressed jobsite, two employees were working inside an eight (8) foot deep excavation which was not inspected by a competent person, thereby exposing the employees to cave in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Dec 5, 2013
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: a. On or about November 18, 2013 - at the above addressed jobsite, two employees were working inside an eight (8) foot deep excavation that was not provided with an adequate protective system, thereby exposing the employees to cave in hazards.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
More inspections in this industry (NAICS 515210)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339492712.