TOLEDO, OH —
OSHA Inspection: CORBY ENERGY SERVICES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CORBY ENERGY SERVICES, INC. in INTERSECTION OF JEFFERSON ST. AND 17TH ST., TOLEDO, OH 43604 (NAICS 237130). OSHA activity number 339493645.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORBY ENERGY SERVICES, INC.
- Site address
- INTERSECTION OF JEFFERSON ST. AND 17TH ST.
- City
- TOLEDO
- State
- OH
- ZIP
- 43604
- Mailing
- PO BOX 970, BELLEVILLE, MI 48112
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 154
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 C02
- Issued
- Dec 12, 2013
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) Corby Energy Services on or about November 19, 2013, at the site located near the intersection of Jefferson St. and 17th St. Toledo, OH: The employer failed to ensure a safe means of egress such as a ladder was provided to an employee installing communication conduit in an 8 ft. deep trench.
Recent events (2)
- — I (O) $2520
- — Z (S) $3600
1926.651 D
- Issued
- Dec 12, 2013
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1926.651(d): Employees exposed to public vehicular traffic were not provided with a warning vest or other suitable garments marked with or made of reflectorized or high-visibility material: (a) Corby Energy Services on or about November 19, 2013, at the site located near the intersection of Jefferson St. and 17th St. Toledo, OH: The employer failed to ensure employees were easily visible to vehicular traffic by ensuring all employees wore high visibility garments while working near or in an active roadway at an excavation. Due to this condition, employees walking and working parallel to the roadway were exposed to potential struck-by injuries caused from a vehicular collision.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1926.652 A01
- Issued
- Dec 12, 2013
- Penalty
- Initial $4,500 · Current $3,070 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). (a) Corby Energy Services on or about November 19, 2013, at the site located near the intersection of Jefferson St. and 17th St. Toledo, OH: The employer failed to ensure employees were adequately protected from cave-ins while installing communication line conduit in an 8 ft. deep trench.
Recent events (2)
- — I (O) $3070
- — Z (S) $4500
1926.652 C04 III
- Issued
- Dec 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(c)(4)(iii): At least one copy of the design was not maintained at the jobsite during construction of the protective system. After that time, the design may be stored off the jobsite, but a copy of the design shall be made available to the Secretary upon request. (a) Corby Energy Services on or about November 19, 2013, at the site located near the intersection of Jefferson St. and 17th St. Toledo, OH: The employer failed to ensure a written copy of the protective shoring system's design and construction was kept onsite during installation. Due to this condition, inadequacies in the protective system's installation and construction were found during employee use. Employees were exposed to potential cave-in hazards when the employer deviated from the specifications of the Professional Engineer's certified plans.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.652 E01 I
- Issued
- Dec 12, 2013
- Abate by
- Dec 23, 2013
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(e)(1)(i): Members of support systems were not securely connected together to prevent sliding, falling, kickouts, or other predictable failure: (a) Corby Energy Services on or about November 19, 2013, at the site located near the intersection of Jefferson St. and 17th St. Toledo, OH: The employer failed to ensure top and bottom horizontal supporting members were adequately secured to the steel side plates of the shoring system, preventing unintentional displacement. In the event of support dislocation employees were exposed to cave-in hazards while working in the 8 ft. deep trench.
Recent events (2)
- — I (S) $0
- — Z (S) $4500
More inspections at Corby Energy Services, INC.
View Corby Energy Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339493645.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.