FORT BRAGG, NC ·
OSHA Inspection: R & M WELDING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of R & M WELDING in DISTRICT SUPERINTENDENT OFFICE, FORT BRAGG, NC 28310 (NAICS 333992). OSHA activity number 339495293.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R & M WELDING
- Site address
- DISTRICT SUPERINTENDENT OFFICE
- City
- FORT BRAGG
- State
- NC
- ZIP
- 28310
- Mailing
- 2956 OLD STAGE RD, COATS, NC 27521
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333992
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.20 B01
- Issued
- Dec 9, 2013
- Abate by
- Jan 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. New District Superintendents Office, Fort Bragg, NC: On or about 11/20/2013, the employer did not develop and implement a safety & health program that addressed workplace hazards such as, but not limitied to safe use of power tools, electrical hazards, accident prevention and Hazard Communication.
Recent events (1)
- · Z (O) $0
1926.405 G02 IV
- Issued
- Dec 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: New District Superintendents Office, Fort Bragg, NC: Extension cord protective cover was damaged. Strain relief was pulled away from the terminal connection..
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 333992)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339495293.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.