Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAPITOL FEED & MILLING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAPITOL FEED & MILLING in 2299 HWY 71, CEDAR CREEK, TX 78612 (NAICS 493130). OSHA activity number 339496499.

Watch Capitol Feed & Milling — free Get an email when a new federal OSHA severe-injury report for Capitol Feed & Milling is published. One employer, no account, unsubscribe in one click.
Site address
2299 HWY 71
City
CEDAR CREEK
State
TX
ZIP
78612
Mailing
2299 HWY 71, CEDAR CREEK, TX 78612
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493130
Employees
7
Ownership type
A

3 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  On or about, November 21, 2013 load rating plates were not affixed on the excess storage platform, exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:  On or about November 21, 2013, the excess storage area on the second level platform that is up to approximately 8 feet high did not include guard rails, exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 D01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(d)(1)(ii): Stairway(s) less than 44 inches wide having one side open, did not have at least one stair railing in accordance with (e)(1) on the open side:  Note: 1910.23(e)(1) A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard.  On or about October 25, 2013, the stairway leading to flat storage did not include standard stair railing with a mid rail, exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339496499.