On , OSHA opened a referral safety inspection of SUMMIT CUSTOM HOMES, LLC. in 504 LAKESIDE DRIVE, LEES SUMMIT, MO 64064 (NAICS 236115). OSHA activity number 339498750.

Watch Summit Custom Homes, LLC. — free Get an email when a new federal OSHA severe-injury report for Summit Custom Homes, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
504 LAKESIDE DRIVE
City
LEES SUMMIT
State
MO
ZIP
64064
Mailing
120 SE 30TH STREET, LEES SUMMIT, MO 64082
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
1
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)    (a) 504 Lakeside Dr, Lee's Summit, MO 64064; Employees were applying EIFS from scaffolding that was not fully planked.     Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $1960
  • — Z (S) $2800

1926.451 C02

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    (a) 504 Lakeside Dr, Lee's Summit, MO 64064; Scaffolding used by employees applying (EIFS) External Insulation and Finishing System was not equipped with base plates, mud sills or other adequate firm foundation. The scaffold rested on wood blocks on the driveway and was cribbed with wood on the mud areas near the house front door. Employees were exposed to potential scaffold collapse hazards.    Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $1960
  • — Z (S) $2800

1926.451 E01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    (a) 504 Lakeside Dr, Lee's Summit, MO 64064; No access ladder was used to access tubular welded scaffolds. Employees were exposed to fall hazards when climbing crossbraces and end panels of the scaffolds. End panels were not configured with uniform rung-like supports.    Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $1960
  • — Z (S) $2800

1926.451 G01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    (a) 504 Lakeside Drive, Lee's Summit, MO 64064; Employees were applying EIFS from the second and third tiers of tubular welded scaffolding. No fall protection was worn and no adequate guard rail system was in place.     Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $1960
  • — Z (S) $2800

1926.452 C02

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.452(c)(2): All brace connections were not secured:    (a) 504 Lakeside Drive, Lee's Summit, MO 64064; Employees were working from scaffolding applying EIFS and were exposed to hazards posed by potential scaffold collapse because some scaffold cross braces were missing.    Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $1400
  • — Z (S) $2000

View SUMMIT CUSTOM HOMES, LLC.'s full OSHA safety record →