Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAPITAL DISTRICT FLOOR COVERING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CAPITAL DISTRICT FLOOR COVERING, INC. in 110 RAILROAD AVENUE, ALBANY, NY 12205 (NAICS 442210). OSHA activity number 339499238.

Watch Capital District Floor Covering, INC. — free Get an email when a new federal OSHA severe-injury report for Capital District Floor Covering, INC. is published. One employer, no account, unsubscribe in one click.
Site address
110 RAILROAD AVENUE
City
ALBANY
State
NY
ZIP
12205
Mailing
110 RAILROAD AVENUE, ALBANY, NY 12205
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
442210
Employees
12
Ownership type
A

4 citations on file for this inspection.

1910.24 H

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1020.00 · Current $500.00 Reduced
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:      a) On or about November 25, 2013 and at times prior thereto in the warehouse; there was an open sided staircase with a handrail only on the closed side.
Recent events (2)
  • — I (S) $500
  • — Z (S) $1020

1910.36 G02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:      a) On or about November 25, 2013 and at times prior thereto in the warehouse; the exit access in the back room measured 20" due to boxes being stored.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.37 B04

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:   a) On or about November 25, 2013 and at times prior thereto at the warehouse; the back exit access route did not have any signs indicating the direction of travel to the back exit door.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   a) On or about November 25, 2013 and at times prior thereto in the warehouse; a quad 120V receptical was not installed into the metal box properly, in that it was not mounted properly in the box.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339499238.