EGG HARBOR TOWNSHIP, NJ ·
OSHA Inspection: STONE CRAFTERS, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of STONE CRAFTERS, LLC in 6084 REEGA AVE., EGG HARBOR TOWNSHIP, NJ 08234 (NAICS 327991). OSHA activity number 339499543.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STONE CRAFTERS, LLC
- Site address
- 6084 REEGA AVE.
- City
- EGG HARBOR TOWNSHIP
- State
- NJ
- ZIP
- 08234
- Mailing
- 6084 REEGA AVE., EGG HARBOR TOWNSHIP, NJ 08234
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 22
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.95 G06
- Issued
- Dec 18, 2013
- Penalty
- Initial $1,700 · Current $1,105 Reduced
81108111
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : Annual audiometric testing was not provided within twelve months of the date of the previous audiometric testing for the employees with the following exposures: a) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 185.8% of the permissible level (90 dBA) and was equivalent to approximately 94.5 dBA. The sampling was performed for 480 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time. b) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 178.6% of the permissible level (90 dBA) and was equivalent to approximately 94.2 dBA. The sampling was performed for 480 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time. c) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 133.5% of the permissible level (90 dBA) and was equivalent to approximately 92.1 dBA. The sampling was performed for 450 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time. d) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 119.4% of the permissible level (90 dBA) and was equivalent to approximately 91.3 dBA. The sampling was performed for 480 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time. e) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 104.1% of the permissible level (90 dBA) and was equivalent to approximately 90.3 dBA. The sampling was performed for 480 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time.
Recent events (2)
- · I (S) $1105
- · Z (S) $1700
1910.95 K02
- Issued
- Dec 18, 2013
- Penalty
- Initial $1,700 · Current $1,105 Reduced
81108111
General-duty citation text
29 CFR 1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program: Annual noise training was not provided within twelve months of the date of the previous training for the employees with the following exposures: a) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 185.8% of the permissible level (90 dBA) and was equivalent to approximately 94.5 dBA. The sampling was performed for 480 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time. b) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 178.6% of the permissible level (90 dBA) and was equivalent to approximately 94.2 dBA. The sampling was performed for 480 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time. c) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 133.5% of the permissible level (90 dBA) and was equivalent to approximately 92.1 dBA. The sampling was performed for 450 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time. d) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 119.4% of the permissible level (90 dBA) and was equivalent to approximately 91.3 dBA. The sampling was performed for 480 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time. e) Bench area - A stone finisher was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 104.1% of the permissible level (90 dBA) and was equivalent to approximately 90.3 dBA. The sampling was performed for 480 minutes during one shift on 12/4/13. Zero exposure was assumed for the unsampled period of time.
Recent events (2)
- · I (S) $1105
- · Z (S) $1700
1910.242 B
- Issued
- Dec 18, 2013
- Penalty
- Initial $1,020 · Current $663 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Bench area - The pressure at the nozzle of a compressed air hose used by an employee to dry a stone counter top was measured at over 100 p.s.i. On or about 11/25/13.
Recent events (2)
- · I (S) $663
- · Z (S) $1020
More inspections at Stone Crafters, LLC
View Stone Crafters, LLC's full OSHA safety record →
More inspections in this industry (NAICS 327991)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339499543.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.