ALLENTOWN, PA ·
OSHA Inspection: ALLENTECH
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALLENTECH in 6350 HEDGEWOOD DR. SUITE 100, ALLENTOWN, PA 18106 (NAICS 423510). OSHA activity number 339499923.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLENTECH
- Site address
- 6350 HEDGEWOOD DR. SUITE 100
- City
- ALLENTOWN
- State
- PA
- ZIP
- 18106
- Mailing
- 6350 HEDGEWOOD DR. SUITE 100, ALLENTOWN, PA 18106
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 74
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Jan 14, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $2,975 · Current $2,231 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolat. (a) Fabrication Shop Area, Power Press Brake Machine - on or about November 25, 2013, an employee was conducting maintenance work on a power press brake had not been provided established company lockout/tag out training at an Authorized level.
Recent events (2)
- · I (S) $2231.25
- · Z (S) $2975
1910.147 D02
- Issued
- Jan 14, 2014
- Abate by
- Feb 3, 2014
- Penalty
- Initial $2,975 · Current $2,231 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the employers energy control procedures required by this standard: (a) Fabrication Shop Area, Power Press Brake Machine - on or about November 25, 2013, the employer failed to shut down or turn off the machine to perform servicing in accordance with their established procedure, thereby exposing employees to the hazards of moving machine parts while they replaced press brake dies as part of the normal production mode of operation. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], stored energy [(d)(5), if applicable], and verification of isolation [(d)(6)], were not implemented to safeguard employees from the machine servicing hazards.
Recent events (2)
- · I (S) $2231.25
- · Z (S) $2975
More inspections in this industry (NAICS 423510)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339499923.