Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NED STEVENS

Foreign inspection · Safety discipline

On , OSHA opened a foreign safety inspection of NED STEVENS in 133 RIVERVIEW AVENUE, NORTH ARLINGTON, NJ 07031 (NAICS 238390). OSHA activity number 339502114.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NED Stevens — free Get an email when a new federal OSHA severe-injury report for NED Stevens is published. One employer, no account, unsubscribe in one click.
Establishment
NED STEVENS
Site address
133 RIVERVIEW AVENUE
City
NORTH ARLINGTON
State
NJ
ZIP
07031
Mailing
11 DANIEL ROAD EAST, FAIRFIELD, NJ 07004
Inspection type
Foreign (L)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
200
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Mar 11, 2014
Abate by
Apr 4, 2014
Penalty
Initial $7,000 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fall from a ladder.  a)  Front of Structure:  Employee was exposed to a fall hazard while operating an ECHO PB-250L power blower while standing on an aluminum extension ladder, on or about 11/26/2013.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.23 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent).  a)  Roof of Residential Structure:  Employees performing gutter cleaning activities did not have means of fall protection in place; thereby, exposing them to fall hazards ranging from approximately 10' to 22', on or about 11/26/2013.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2014
Penalty
Initial $6,000 · Current $3,000 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment.    a)  Roof of Residential Structure:  Employee performing gutter cleaning activities was using an ECHO model PB-250LN power blower without wearing eye protection, on or about 11/26/2013.
Recent events (3)
  • — F (S) $3000
  • — C (S) $6000
  • — Z (S) $6000

View NED Stevens's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339502114.