PHILADELPHIA, PA —
OSHA Inspection: BART EMANUEL AND SON PLUMBING AND HEATING, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BART EMANUEL AND SON PLUMBING AND HEATING, LLC in 1601 S. 49TH STREET, PHILADELPHIA, PA 19143 (NAICS 237110). OSHA activity number 339506495.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BART EMANUEL AND SON PLUMBING AND HEATING, LLC
- Site address
- 1601 S. 49TH STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19143
- Mailing
- 1505 BEULAH STREET, PHILADELPHIA, PA 19147
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 B03
- Issued
- May 30, 2014
- Abate by
- Jun 5, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(b)(3): When excavation operations approached the estimated location of underground installations, the exact location of the installations was not determined by safe and acceptable means: a) Jobsite, 1601 S. 49th Street - The exact location of the 13.2 kV electric lines running across the excavation was not determined by a safe and acceptable means. The terra cotta insulation around the electric lines was damaged and broken off, exposing employees to potential electrical hazards. Observed on or about 12/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.651 B04
- Issued
- May 30, 2014
- Abate by
- Jun 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(b)(4): While the excavation was opened, underground installations were not protected, supported or removed as necessary to safeguard employees: a) Jobsite, 1601 S. 49th Street - Underground 13.2 kV electric lines in the excavation were not protected, supported or removed, exposing employees to potential electrical hazards. Observed on or about 12/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 K01
- Issued
- May 30, 2014
- Abate by
- Jun 5, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person prior to the start of work, and as needed throughout the shift, for evidence of situations that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions: a) Jobsite, 1601 S. 49th St., Philadelphia - Inspections of the 25 feet deep excavation were not conducted by a competent person, daily, prior to the start of work and as needed throughout the shift, exposing employees to cave-in hazards and potential electrical hazards. Observed on or about 12/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.21 B02
- Issued
- May 30, 2014
- Abate by
- Jun 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Jobsite, 1601 S. 49th St., Philadelphia - The employer did not instruct each employee excavating the soil around the electric lines and entering into the excavation, in the recognition, evaluation and control of unsafe conditions and the regulations applicable to his work environment, exposing the employees to cave-in hazards and potential electrical hazards. Observed on or about 12/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- May 30, 2014
- Abate by
- Jun 5, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance paragraph (b) or (c) of 29 CFR 1926.652: a) Jobsite, 1601 S. 49th St., Philadelphia - Employees walking and operating equipment on the ramp into the excavation in Type C soil were not protected from cave-ins. The walls of the ramp were approximately 6 to 8 feet deep and on the side closest to the building they were continuous with the spoil pile which was approximately 10 feet high. The walls of the ramp and the spoil pile were sloped at an angle steeper than one and one-half horizontal to one vertical (34 degrees from the horizontal). Observed on or about 12/3/13. b) Jobsite, 1601 S. 49th St., Philadelphia - An employee walking on planks on top of a trench box in an excavation in Type C soil approximately 25 feet deep, 30 feet wide and 30 feet long, was not protected from cave-ins. The excavation walls sloped at an angle steeper than one and one-half horizontal to one vertical (34 degrees from the horizontal). Observed on or about 12/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections at Bart Emanuel and SON Plumbing and Heating, LLC
View Bart Emanuel and SON Plumbing and Heating, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339506495.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.