SAUGERTIES, NY —
OSHA Inspection: D&B ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D&B ROOFING, INC. in 626 ROUTE 212, SAUGERTIES, NY 12477 (NAICS 238160). OSHA activity number 339507048.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D&B ROOFING, INC.
- Site address
- 626 ROUTE 212
- City
- SAUGERTIES
- State
- NY
- ZIP
- 12477
- Mailing
- 15 COLLINS LANE, SAUGERTIES, NY 12477
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B02
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): (a) At the jobsite - on or about December 3, 2013 - jobsite was not inspected by a competent person to identify and correct hazardous conditions associated with roofing work.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.95 A
- Issued
- Jan 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: (a) At the jobsite - on or about December 3, 2013 - employees were installing roof shingles with pneumatic nail guns without wearing eye protection, such as safety glasses with side shields.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Jan 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) At the jobsite - on or about December 3, 2013 - the roof access ladder located at the rear of the building did not extend the requisite three feet above the upper surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jan 28, 2014
- Penalty
- Initial $1,360 · Current $1,020 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) At the jobsite - on or about December 3, 2013 - a fall hazard of approximately 17 feet existed when employees were installing roof shingles on a 7 on 12 pitched roof deck without any conventional fall protection.
Recent events (2)
- — I (S) $1020
- — Z (S) $1360
1926.503 A01
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) At the jobsite - on or about December 3, 2013 - the employer did not provide a fall protection training program to the employees that were performing shingle installations on a 7 on 12 pitched roof deck.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 B01
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: (a) At the jobsite- on or about December 3, 2013 - the employer does not have certification of fall protection training for the employees that perform roofing work on steep pitched roof decks.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at D&B Roofing, INC.
View D&B Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339507048.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.