KINGS POINT, NY —
OSHA Inspection: AIRSEAL INSULATION SYSTEMS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AIRSEAL INSULATION SYSTEMS in 40 SHORE DRIVE, KINGS POINT, NY 11024 (NAICS 238310). OSHA activity number 339507477.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIRSEAL INSULATION SYSTEMS
- Site address
- 40 SHORE DRIVE
- City
- KINGS POINT
- State
- NY
- ZIP
- 11024
- Mailing
- 234 6TH STREET, BROOKLYN, NY 11215
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 30
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 E01
- Issued
- Jun 2, 2014
- Abate by
- Jun 16, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Worksite: Employees climbed the outside of the scaffold to access the work platform; on or about 12/4/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $2800
- — Z (S) $2800
1926.95 A
- Issued
- Jun 2, 2014
- Abate by
- Jun 25, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) Worksite - Protective suit worn by the employee during the spray foam insulation operation was ripped and had holes limiting the effectiveness and reliability of the suit, on or about 12/4/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E02
- Issued
- Jun 2, 2014
- Abate by
- Jun 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(2): The employer that produced, used, or stored hazardous chemicals at the workplace in such a way that employees of other employer(s) could be exposed did not ensure that the hazard communication program included all of the elements outlined in 29 CFR 1910.1200(e)(2)(i) through 29 CFR 1910.1200(e)(2)(iii): (Construction Reference: 1926.59) a) Worksite - Employees use Icynene MD-C-200 Foam containing 100% Polyurethane Foam to spray foam insulation inside of a newly renovated house without providing the other companies onsite with a copy of the safety data sheets; on or about 12/4/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Jun 2, 2014
- Abate by
- Jul 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information (Construction Reference: 1926.59): a) Worksite - Employees use Icynene MD-C-200 Foam containing 100% Polyurethane Foam to spray foam insulation inside of a newly renovated house without being provided training regarding the new label elements and safety data sheets format by December 1, 2013; on or about 12/4/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Airseal Insulation Systems
View Airseal Insulation Systems's full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339507477.