LONDONDERRY, NH —
OSHA Inspection: AEROFLEX/METELICS, INC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of AEROFLEX/METELICS, INC in 54 GRENIER FIELD ROAD, LONDONDERRY, NH 03053 (NAICS 334413). OSHA activity number 339508178.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AEROFLEX/METELICS, INC
- Site address
- 54 GRENIER FIELD ROAD
- City
- LONDONDERRY
- State
- NH
- ZIP
- 03053
- Mailing
- 54 GRENIER FIELD ROAD, LONDONDERRY, NH 03053
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334413
- Employees
- 82
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 A05
- Issued
- Mar 21, 2014
- Abate by
- May 7, 2014
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: Basement - The Hyster fork truck had an extension which was used approximately once/week. These modifications or additions which affect capacity and safe operation of the powered industrial truck were performed by the employer without the manufacturer's prior written approval.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.305 C04
- Issued
- Mar 21, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(c)(4): Faceplates for flush-mounted snap switches. Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface: Basement - The faceplate for the switch controlling the heater on the side of the gas cabinet for reactor 3 was broken and did not completely cover the opening of the box.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.101 B
- Issued
- Mar 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: Hazardous Waste Storage Room - Some of the compressed gas cylinders stored in this room were not secured to prevent them from being knocked over.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 334413)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339508178.