Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WORLD WIDE EXCHANGERS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WORLD WIDE EXCHANGERS INC. in 601 W. 136TH ST., SKIATOOK, OK 74070 (NAICS 332999). OSHA activity number 339508426.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch World Wide Exchangers INC. — free Get an email when a new federal OSHA severe-injury report for World Wide Exchangers INC. is published. One employer, no account, unsubscribe in one click.
Site address
601 W. 136TH ST.
City
SKIATOOK
State
OK
ZIP
74070
Mailing
P.O. BOX 47, SKIATOOK, OK 74070
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
23
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 18, 2014
Abate by
Apr 8, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about December 3, and 4 , 2013 the employer did not ensure that each person who operated a powered industrial truck (forklift) had been properly trained.  Employees were exposed to struck by, caught-in and crushing hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 18, 2014
Abate by
Apr 8, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   On or about December 3, 2013 and at times prior thereto machine guarding was not in place to prevent employee exposure to sharp machine chips and tailings produced during machine drilling operations on the Giddings and Lewis drill dye machine. Employees were exposed to laceration and struck-by hazards.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.219 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 18, 2014
Abate by
Apr 8, 2014
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o).   On or about December 3, 2013 and at times prior thereto an Oliver brand drill sharpener located in the machine shop did not have guards in place exposing rotating belts and pulleys.  Employees were exposed to the hazards of struck by and caught in.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.303 G02 I

Serious Gravity 1 3 instances 10 exposed
Issued
Mar 18, 2014
Abate by
Apr 8, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  On or about December 3, 2013 and at times prior thereto, electrical panel boxes, power distribution panels and junction boxes were found with open knockouts not effectively closed and exposing live parts. The condiction exposed employees to the hazard of electric shock hazard.  Instance 1:    Electrical Panel Box in Exchanger Build Shop Area WW1   Instance 2:    Electrical Panel Box in Machine Shop Bldg. WW2
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.212 B

Other-than-serious 3 instances 4 exposed
Issued
Mar 18, 2014
Abate by
Apr 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving.  On or about December 3, 2013 and at times prior to, in the Machine shop area, stationary grinders and drill machines on stands were not mounted to the floor. Exposing employees to struck by and caught in hazards from machine movement during operation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View World Wide Exchangers INC.'s full OSHA safety record →