MANCHESTER, NH —
OSHA Inspection: MSN CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MSN CORPORATION in 431 SOMERVILLE ST., MANCHESTER, NH 03103 (NAICS 311612). OSHA activity number 339508657.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MSN CORPORATION
- Site address
- 431 SOMERVILLE ST.
- City
- MANCHESTER
- State
- NH
- ZIP
- 03103
- Mailing
- 431 SOMERVILLE ST., MANCHESTER, NH 03103
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 55
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 24, 2014
- Abate by
- Jan 30, 2014
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points: a. Dough Conveyor - Employees were not protected from amputations while working near the dough conveyor which had two unguarded ingoing nip points created by the gap between the existing guards and the chains which propelled the trays.
Recent events (2)
- — I (O) $0
- — Z (S) $3500
1910.303 F02
- Issued
- Jan 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Electric Panel "K" - Each disconnecting mean within the electrical cabinet was not labeled.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Jan 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. Electric Panel "L" - An opening in the electrical cabinet was not effectively closed when a 1/2 inch insulated wire was ran through a 3 inch knockout in the side of the cabinet leaving an opening.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at MSN Corporation
View MSN Corporation's full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339508657.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.