Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MSN CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MSN CORPORATION in 431 SOMERVILLE ST., MANCHESTER, NH 03103 (NAICS 311612). OSHA activity number 339508657.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MSN Corporation — free Get an email when a new federal OSHA severe-injury report for MSN Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
MSN CORPORATION
Site address
431 SOMERVILLE ST.
City
MANCHESTER
State
NH
ZIP
03103
Mailing
431 SOMERVILLE ST., MANCHESTER, NH 03103
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311612
Employees
55
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Other-than-serious 1 instance 3 exposed
Issued
Jan 24, 2014
Abate by
Jan 30, 2014
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points:    a. Dough Conveyor - Employees were not protected from amputations while working near the dough conveyor which had two unguarded ingoing nip points created by the gap between the existing guards and the chains which propelled the trays.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

1910.303 F02

Other-than-serious 1 instance 3 exposed
Issued
Jan 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    Electric Panel "K" - Each disconnecting mean within the electrical cabinet was not labeled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 3 exposed
Issued
Jan 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:     a. Electric Panel "L" - An opening in the electrical cabinet was not effectively closed when a 1/2 inch insulated wire was ran through a 3 inch knockout in the side of the cabinet leaving an opening.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View MSN Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339508657.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.