CLIFTON PARK, NY ·
OSHA Inspection: CLIFF STRACHAN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CLIFF STRACHAN in 53 TIPPERARY ROAD, CLIFTON PARK, NY 12065 (NAICS 238170). OSHA activity number 339509556.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLIFF STRACHAN
- Site address
- 53 TIPPERARY ROAD
- City
- CLIFTON PARK
- State
- NY
- ZIP
- 12065
- Mailing
- 1027 CHRISLER AVENUE, SCHENECTADY, NY 12303
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B02
- Issued
- Feb 20, 2014
- Abate by
- Feb 26, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): (a) Front of Building - on or about December 5, 2013 - the employer did not inspect the electrical tools and equipment on site for damage. Also, the electrical equipment was not inspected for necessary protective equipment, such as grounding conductors and a Ground Fault Circuit Interrupter.
Recent events (1)
- · Z (S) $1200
1926.404 B01 I
- Issued
- Feb 20, 2014
- Abate by
- Feb 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: (a) Front of Building - on or about December 5, 2013 - the Ryobi CSB123 circular saw, serial# CS09252 98581, that was used to cut vinyl siding was not protected by a Ground Fault Circuit Interrupter (GFCI).
Recent events (1)
- · Z (S) $0
1926.404 F06
- Issued
- Feb 20, 2014
- Abate by
- Feb 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) Front of Building - on or about December 5, 2013 - the electrical extension cord that was supplying power to the Ryobi CSB123 circular saw, serial# CS09252 98581, was not equipped with a grounding conductor.
Recent events (1)
- · Z (S) $0
1926.416 E01
- Issued
- Feb 20, 2014
- Abate by
- Feb 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) Front of Building - on or about December 5, 2013 - the electrical cord that was attached to the Ryobi CSB123 circular saw, serial# CS09252 98581, had insulation damage.
Recent events (1)
- · Z (S) $0
1926.501 B13
- Issued
- Feb 20, 2014
- Abate by
- Feb 26, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) Front Canopy of the Building - on or about December 5, 2013 - no fall protection was available for the employees that were installing vinyl siding. Work elevation was approximately 11 feet.
Recent events (1)
- · Z (S) $1600
1926.503 A01
- Issued
- Feb 20, 2014
- Abate by
- Feb 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Front Canopy of the Building - on or about December 5, 2013 - the employer did not provide a fall protection training program for the employees that were installing vinyl siding.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238170)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339509556.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.