Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: NAVASOTA CONCRETE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NAVASOTA CONCRETE, INC. in 5970 FM 3455, NAVASOTA, TX 77868 (NAICS 327320). OSHA activity number 339510349.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Navasota Concrete, INC. for free Get an email when a new federal OSHA severe-injury report for Navasota Concrete, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5970 FM 3455
City
NAVASOTA
State
TX
ZIP
77868
Mailing
5970 FM 3455, NAVASOTA, TX 77868
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
15
Ownership type
Private (A)

4 citations on file for this inspection.

1910.303 B07 IV

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 23, 2014
Abate by
Feb 7, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated.    On or about December 4, 2013, damaged electrical equipment in the following instances exposed employees to an electrical hazard:    a:  The extension cord powering the Makita 355 mm Portable Cut-Off Wheel had a damaged outer sheathing exposing the internal wiring.      b:  Conduit on the outer wall of the batch plant powering the light in the plant bay had separated, exposing the internal wiring.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 23, 2014
Abate by
Feb 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   On or about December 4, 2013, the outer sheath of the extension cord powering the concrete vibrator in the maintenance shop was pulled away from the plug showing the inner wiring, exposing employees to an electrical hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 23, 2014
Abate by
Feb 7, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   On or about December 4, 2013, the flexible cord powering the Makita 355 mm Portable Cut-Off Wheel was affixed to the wall and roof and used as permanent wiring, exposing employees to an electrical hazard.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.305 G01 IV D

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 23, 2014
Abate by
Feb 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces:   On or about December 4, 2013, the flexible cord powering the Makita 355 mm Portable Cut-Off Wheel was affixed to the wall and roof and used as permanent wiring, exposing employees to an electric shock hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339510349.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.