SAINT CLAIR, PA —
OSHA Inspection: POLYFLO, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of POLYFLO, INC. in 2 TENSION WAY, SAINT CLAIR, PA 17970 (NAICS 325211). OSHA activity number 339514341.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- POLYFLO, INC.
- Site address
- 2 TENSION WAY
- City
- SAINT CLAIR
- State
- PA
- ZIP
- 17970
- Mailing
- 2 TENSION WAY, SAINT CLAIR, PA 17970
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 27
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.37 A03
- Issued
- Jan 23, 2014
- Abate by
- Feb 4, 2014
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Granulation area; A 34 inch wide exit door was blocked by a scaffold platform, on or about 12/10/2013. Abatement Certification Required
Recent events (2)
- — I (O) $0
- — Z (S) $2100
1910.242 B
- Issued
- Jan 23, 2014
- Abate by
- Mar 10, 2014
- Penalty
- Initial $2,800 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Extrusion area; Sixteen compressed air guns operating at 90 psi. were used to clean plastic and clothing, on or about 12/10/2014. b) Separation area; Seven compressed air guns operating at 90 psi. were used to clean plastic and clothing, on or about 12/10/2014. c) Granulation area; Thirteen compressed air guns operating at 90 psi. were used to clean plastic and clothing, on or about 12/10/2014. Abatement Certification Required
Recent events (2)
- — I (S) $2500
- — Z (S) $2800
1910.305 G02 III
- Issued
- Jan 23, 2014
- Abate by
- Feb 4, 2014
- Penalty
- Initial $2,100 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Shipping & Receiving / Dock Plate area; A 110 volt flexible cord that powers a Weigh Tronix scale was not provided with strain relief, on or about 12/10/2013. Abatement Certification Required
Recent events (2)
- — I (S) $2000
- — Z (S) $2100
More inspections at Polyflo, INC.
View Polyflo, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339514341.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.