MCALESTER, OK —
OSHA Inspection: ATLANTIC MEECO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ATLANTIC MEECO in 1501 EAST ELECTRIC AVE., MCALESTER, OK 74501 (NAICS 332311). OSHA activity number 339515272.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ATLANTIC MEECO
- Site address
- 1501 EAST ELECTRIC AVE.
- City
- MCALESTER
- State
- OK
- ZIP
- 74501
- Mailing
- 1501 EAST ELECTRIC AVE., MCALESTER, OK 74501
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332311
- Employees
- 29
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.95 C01
- Issued
- Apr 11, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $4,900 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8 hour time weighted average sound level (TWA) of 85 dBA: On or about April 2, 2014, the employer did not administer a continuing and effective hearing conservation program for employees with an 8-hour time-weighted average exposure greater than 85 dBA exposing employees to the hazard of hearing loss.
Recent events (2)
- — I (S) $2400
- — Z (S) $4900
1910.95 D01
- Issued
- Apr 11, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: On or about April 2, 2014, the employer did not develop and implement a monitoring program for employees with an 8-hour time-weighted average exposure greater than 85 dBA exposing employees to the hazard of hearing loss.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 G05 I
- Issued
- Apr 11, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(g)(5)(i): The employer did not establish, within 6 months of an employee's first exposure at or above the action level, a valid baseline audiogram against which subsequent audiograms can be compared: On or about April 2, 2014, the employer did not establish a baseline audiogram for all employees exposed to noise above an 8-hour time-weighted average exposure greater than 85 dBA exposing employees to the hazard of hearing loss.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Apr 11, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $3,500 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about December 10, 2013, the employer did not maintain sufficient access and working space around all electric equipment exposing employees to the hazard of contact-with electricity resulting in electrical shock.
Recent events (2)
- — I (S) $1700
- — Z (S) $3500
1910.334 A04
- Issued
- Apr 11, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(4): Portable electric equipment and flexible cords used in highly conductive work locations (such as those inundated with water or other conductive locations) or in job locations where employees were likely to contact water or conductive liquids were not approved for those locations: On or about December 10, 2013, the employer did not ensure all electric equipment and flexible cords used in the shop in areas where water accumulates on the floor from leaks in the roof are approved for use in a wet location exposing employees to the hazard of contact-with electricity resulting in electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Apr 11, 2014
- Abate by
- Apr 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about December 10, 2013, the employer did not provide employees voluntarily wearing N95 filtering face-piece respirators with Appendix D to the Respiratory Protection standard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Apr 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable Fire Extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about December 10, 2013, the employer did not maintain clear access to all fire extinguishers provided for employee use exposing employees to the hazard of fire and smoke inhalation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E03
- Issued
- Apr 11, 2014
- Abate by
- Apr 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: On or about December 10, 2013, the employer did not ensure all fire extinguishers provided for employee use had received an annual maintenance check exposing employees to the hazard of fire and smoke inhalation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Apr 11, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about December 10, 2013, the employer did not provide Hazard Communication training to employees using chemicals such as, but not limited to, isopropyl alcohol, Lube Matic Wire Kleener and Lubricant, Radnor Nozzle Gel, Fabulous Blaster and WD-40 exposing employees to the hazard of contact with hazardous chemicals.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Atlantic Meeco
View Atlantic Meeco's full OSHA safety record →
More inspections in this industry (NAICS 332311)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339515272.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.