WASHINGTON, DC —
OSHA Inspection: MARK IV BUILDERS, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARK IV BUILDERS, INC in 1900 JACKSON ST., NW, WASHINGTON, DC 20018 (NAICS 236117). OSHA activity number 339516635.
Where did this inspection happen?
- Establishment
- MARK IV BUILDERS, INC
- Site address
- 1900 JACKSON ST., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20018
- Mailing
- #1 TOMLINSON COURT, CABIN JOHN, MD 20818
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236117
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.95 A
- Issued
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) An employee on the second floor of the structure was using a circular saw to cut wood without eye protection exposing him to struck-by hazards, on or about 12/11/13.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1926.100 A
- Issued
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Employees at the main entrance to the structure without head protection were exposed to overhead struck-by hazards from the sub-contractor, on or about 12/11/13.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1926.405 A02 II I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. a) A sub-contractor's employee in the basement used an orange and black extension cord to power a reciprocating saw that had the main sheathing pulled away in multiple places, exposing the employee to electrical hazards, on or about 01/13/14. b) A sub-contractor's employees on the first level usied an orange extension cord to power the circular saw that had the main sheathing pulled away in multiple places, exposing the employees to electrical hazards, on or about 01/13/14. c) Sub-contractor's employees on the second level used an orange and black extension cord to power a circular saw which had the main sheathing pulled away in multiple places, exposing the employees to electrical hazards, on or about 01/13/14. For the purposes of this inspection, this employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1926.405 G02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) A sub-contractor's employee in the basement used the general contractor's supplied orange extension cord that had the sheathing pulled away from the plug attachment, exposing the employee to electrical hazards, on or about 01/13/14. b) Sub-contractor's employees on the first level used an orange extension cord that had the sheathing pulled away from the plug attachment, exposing the employees to electrical hazards, on or about 01/13/14. For the purposes of this inspection, this employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) A sub-contractor's employee worked from the second level of the structure installing roof trusses for the porch without fall protection, exposed to a fall hazard of approximately 10 feet 11 inches, on or about 12/11/13. b) Employees working from the first and second level decks of the structure installing rails without fall protection were exposed to a fall hazard of approximately 10 feet 4 inches to 21 feet, on or about 01/13/14. For the purposes of this inspection, this employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1926.1053 B13
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) A sub-contract's employee on the first level used the top of the four foot stepladder as a step exposing him to fall hazards, on or about 01/13/14. For the purposes of this inspection, this employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) A sub-contractor's employee on the first level used the four foot stepladder with the crossbrace pulled away from the frame of the ladder, exposing him to fall hazards, on or about 01/13/14. For the purposes of this inspection, this employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(b)(2): In an energized installation, each outlet box did not have a cover, faceplate, or fixture canopy: a) A sub-contractor's employee used the general contractor's supplied orange extension cord in the basement plugged into a GFCI protected outlet with no cover, on or about 01/13/14. b) Sub-contractor's employees on the first level used an orange extension cord plugged into a GFCI protected outlet with no cover, on or about 01/13/14. c) Sub-contractor employees on the second level were using an orange and black extension cord plugged into a GFCI protected outlet with no cover, on or about 01/13/14. For the purposes of this inspection, this employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at MARK IV BUILDERS, INC
ARLINGTON, VA—2004-07-06 00:00:00
MARK IV BUILDERS, INC.
GAITHERSBURRG, MD—1994-09-08 00:00:00
MARK IV BUILDERS, INC.
PERIODOT, AZ—1984-12-10 00:00:00
MARK IV BUILDERS INC
View MARK IV BUILDERS, INC's full OSHA safety record →
More inspections in this industry (NAICS 236117)
BOTHELL, WA—2026-07-16 00:00:00
WA317992092 - HARBOUR HOMES LLC
NEWPORT BEACH, CA—2026-07-16 00:00:00
TRADEMARK CONSTRUCTION COMPANY, INC.
BATAVIA, OH—2026-07-09 00:00:00
FISCHER SINGLE FAMILY HOMES IV, LLC
DOWNINGTOWN, PA—2026-07-09 00:00:00
NVR, INC.
WINSTON SALEM, NC—2026-07-08 00:00:00
161508 - CLAYTON PROPERTIES GROUP, INC.
More inspections in DC
WASHINGTON, DC—2026-06-30 00:00:00
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16 00:00:00
MACY'S
WASHINGTON, DC—2026-06-02 00:00:00
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02 00:00:00
DDC CPL LLC
WASHINGTON, DC—2026-06-02 00:00:00
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339516635.