STEELVILLE, MO —
OSHA Inspection: POLY SYSTEMS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of POLY SYSTEMS INC. in #3 INDUSTRIAL DRIVE, STEELVILLE, MO 65565 (NAICS 326122). OSHA activity number 339518144.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- POLY SYSTEMS INC.
- Site address
- #3 INDUSTRIAL DRIVE
- City
- STEELVILLE
- State
- MO
- ZIP
- 65565
- Mailing
- P.O. BOX 1157, STEELVILLE, MO 65565
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326122
- Employees
- 13
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 17, 2013
- Abate by
- Feb 5, 2014
- Penalty
- Initial $2,200 · Current $1,540 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employee(s) in that employee(s) were exposed to the hazard of caught-by: Inside of the Production Area, employee(s) were exposed to an amputation/laceration hazard due to a possible machine process malfunction on the following equipment: a/ JET Lathe, m/n 1440-3PGH, unknown s/n. One method of abatement to correct this apparent hazard is to install emergency stop devices as required by ANSI B11.6-2001, paragraph 6.12.3. DISCLAIMER: a/ The employer is not limited to the abatement method(s) suggested by OSHA. b/ The employer is responsible for selecting and implementing an effective abatement method.
Recent events (2)
- — I (S) $1540
- — Z (S) $2200
1910.212 A01
- Issued
- Dec 17, 2013
- Abate by
- Feb 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a/ Inside of the Production Area, the chuck belonging to a JET Lathe, m/n 1440-3PGH, unknown s/n, was unguarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Dec 17, 2013
- Abate by
- Feb 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: a/ The workplace hazard assessment was not certified.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C01
- Issued
- Dec 17, 2013
- Abate by
- Feb 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a/ A written lockout/tagout program was not developed in writing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 F02
- Issued
- Dec 17, 2013
- Abate by
- Feb 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a/ Inside of the Production Area, the circuit breaker panel boxes were not labeled to identify the amount of voltage each system contained.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Poly Systems INC.
View Poly Systems INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326122)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339518144.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.