Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EAGLE STUD MILL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EAGLE STUD MILL, INC. in 52 FARM TO MARKET ROAD, HALL, MT 59837 (NAICS 321113). OSHA activity number 339519985.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eagle Stud Mill, INC. — free Get an email when a new federal OSHA severe-injury report for Eagle Stud Mill, INC. is published. One employer, no account, unsubscribe in one click.
Site address
52 FARM TO MARKET ROAD
City
HALL
State
MT
ZIP
59837
Mailing
P.O.BOX 29, HALL, MT 59837
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
8
Ownership type
A

9 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 3 instances 6 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) Cutoff Saw Area:  On or about December 10, 2013 and at times prior, employees were exposed to unexpected energization during maintenance operations such as but not limited to, replacing saw blades or clearing jammed lumber from the saw.    (b) Peeler Areas: On or about December 10, 2013 and at times prior, employees were exposed to unexpected energization during maintenance operations such as but not limited to, clearing jammed lumber from the peelers.    (c) Green Chain Area:  On or about December 10, 2013 and at times prior, employees were exposed to unexpected energization during maintenance operations such as but not limited to, clearing lumber from the conveyor.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.219 C02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    (a) Eagle Stud Mill: On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards due to the unguarded horizontal shaft on the conveyor west of the cutoff saw. The rotating shaft was approximately 12 inches in length and approximately six feet from the ground.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.219 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:    (a) Eagle Stud Mill: On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards while working around unguarded shafts on machinery such as, but not limited to conveyors and peelers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 10 2 instances 6 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):     (a) Conveyor off of #1 peeler:  On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards from an ingoing nip point from equipment such as but not limited to the unguarded pulleys on the conveyor chain off of the #1 peeler.    (b) Peeler Areas: On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards from an ingoing nip point from equipment such as but not limited to the unguarded pulleys on the peelers.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.219 E01 I

Serious Gravity 10 2 instances 6 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:    (a) Conveyor off of #1 peeler:  On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards from an ingoing nip point from equipment such as but not limited to the unguarded belts on the conveyor chain off of the #1 peeler.    (b) Peeler Areas: On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards from an ingoing nip point from equipment such as but not limited to the unguarded belts on the peelers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 10 3 instances 8 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven feet or less above floors or platforms were not enclosed:    (a) Conveyors:  On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards from equipment such as but not limited to the unguarded sprocket wheels and chains on the conveyors on site.    (b) Peeler Areas: On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards from equipment such as but not limited to the unguarded sprocket wheels and chains on the peelers and pointers.    (c) Green Chain Area:  On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards from equipment such as but not limited to the unguarded sprocket wheels and chains on the Green chain.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.265 C18 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.265(c)(18)(i):  Construction, operation, and maintenance of conveyors were not in accordance with American National Standard B20.1-1957, which is incorporated by reference as specified in Sec. 1910.6  Means were not provided to guard against accidental injury to personnel at conveyor transfer, loading, or discharge point(s):     (a) Peeler area:  On or about December 10, 2013 and at times prior, employees were exposed to amputation hazards from equipment such as but not limited to the unguarded pulley(s), sprocket(s), sheave(s), drum(s) and block(s) on the conveyor and conveyor end.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 B02 I

Serious Gravity 10 3 instances 10 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    (a) Cutoff Saw Building:  On or about December 10, 2013 and at times prior, employees were exposed to electrical shock and fire hazards while working near the wall with open electrical conductors.      (b)#1 Peeler: On or about December 10, 2013 and at times prior, employees were exposed to electrical shock and fire hazards while working in near the electric motor with open electrical conductors.    (c)  Cutoff Saw: On or about December 10, 2013 and at times prior, employees were exposed to electrical shock and fire hazards while working in near the conveyor with open electrical conductors.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 G02 II

Serious Gravity 10 1 instance 10 exposed
Issued
Jun 9, 2014
Abate by
Jul 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    (a) Green Chain Conveyor:  On or about December 10, 2013 and at times prior, employees were exposed to electrical shock and fire hazards from spliced electrical cords used to supply electrical energy to the Ready Heater brand space heater.    (b) Peelers: On or about December 10, 2013 and at times prior, employees were exposed to electrical shock and fire hazards from spliced electrical cords used to supply electrical energy to the conveyor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Eagle Stud Mill, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339519985.