Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OILFIELD PIPE & SUPPLY, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of OILFIELD PIPE & SUPPLY, INC. in 14861 N 3980 RD, DEWEY, OK 74029 (NAICS 423830). OSHA activity number 339521320.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oilfield Pipe & Supply, INC. — free Get an email when a new federal OSHA severe-injury report for Oilfield Pipe & Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
14861 N 3980 RD
City
DEWEY
State
OK
ZIP
74029
Mailing
PO BOX 189, DEWEY, OK 74029
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423830
Employees
150
Ownership type
A

3 citations on file for this inspection.

1910.179 G01 IV

Serious Gravity 5 3 instances 6 exposed
Issued
Jan 29, 2014
Abate by
Feb 10, 2014
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.179(g)(1)(iv): Multiple conductor cable was used with a suspended pushbutton station, but the station was not supported in some satisfactory manner that protected the electrical conductors against strain:  Oilfield Pipe and Supply Fabrication Shop, Dewey, OK: On or about December 13, 2013, the employer did not support the suspended pushbutton station used with overhead cranes to protect the electrical conductors from strain exposing employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.179 L03 III A

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 29, 2014
Abate by
Feb 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.179(l)(3)(iii)(a): Crane hooks showing defects described in paragraph (j)(2)(iii) of this section shall be discarded:  Oilfield Pipe and Supply Fabrication Shop, Dewey, OK: On or about December 13, 2013, the employer allowed employees to use an overhead crane with a bent hook to move completed items from the work table exposing employees to hazards such as, but not limited to, struck-by.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 25 exposed
Issued
Jan 29, 2014
Abate by
Feb 10, 2014
Penalty
Initial $3,375 · Current $2,025 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Oilfield Pipe and Supply Fabrication Shop, Dewey, OK: On or about December 13, 2013, the employer did not maintain sufficient access and working space around all electric equipment exposing employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $2025
  • — Z (S) $3375

View Oilfield Pipe & Supply, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339521320.