Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: FILTRATION PRODUCTS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FILTRATION PRODUCTS in 1218 N HACKBERRY, SAN ANTONIO, TX 78202 (NAICS 332510). OSHA activity number 339521528.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Filtration Products for free Get an email when a new federal OSHA severe-injury report for Filtration Products is published. One employer, no account, unsubscribe in one click.
Establishment
FILTRATION PRODUCTS
Site address
1218 N HACKBERRY
City
SAN ANTONIO
State
TX
ZIP
78202
Mailing
1218 N HACKBERRY, SAN ANTONIO, TX 78202
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332510
Employees
6
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 10, 2014
Penalty
Initial $2,800 · Current $1,620 Reduced
OSH ACT of 1970 Section (5)(a)(1): OSH ACT of 1970 Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: struck by hazards caused by the movement of the well servicing rig when lifting assembly components:        On or about December 16, 2013 and at times prior thereto employees were exposed to a struck by hazard while using pleator machines powered by compressed air that was transported by Polyvinyl Chloride (PVC) Piping.
Recent events (2)
  • · I (S) $1620
  • · Z (S) $2800

1910.141 A05

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 10, 2014
Abate by
May 15, 2014
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.141(a)(5): A continuing and effective extermination program was not instituted where rodents, insects, or other vermin were detected. Enclosed workplaces were not so constructed, equipped, and maintained as to prevent the entrance or harborage of rodents, insects, or other vermin:        On or about December 16, 2013, and at times prior thereto, employees were exposed the health hazard of rodent feces and urine which would lead to diseases such as Hantavirus and Leptospirosis while operating main shop floor and utilizing multiple machinery during normal operations.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1910.212 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Apr 10, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:         a)    On or about December 16, 2013, and at time prior thereto employees were exposed to a caught-in hazard while operating the Automated Conveyor Systems with Baldor Reliance Model VM3538      b)    On or about December 16, 2013, and at time prior thereto employees were exposed to a caught-in hazard while operating the Hot Melt Laminator (model: prototype)
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.303 B07 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 10, 2014
Abate by
Apr 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:        On or about December 16, 2013 and at time prior thereto, employees were exposed to an electrical hazard from a missing cap on the electrical raceway to the Champion Advantage Series air compressor (model HR10-12, serial number R0010640) .
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.303 G02 I

Other-than-serious 2 instances 5 exposed
Issued
Apr 10, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):     a) On or about December 16, 2013 an at time prior thereto, employees were exposed to an electrical hazard from live electrical wires hanging from the ceiling after removing the drop tile ceilings to eliminate rodents in the office..          b) On or about December 16, 2013 an at time prior thereto, employees were exposed to an electrical hazard from live electrical wires hanging from the ceiling after removal of machinery in the middle of the warehouse.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2800

1910.305 A02 X

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 10, 2014
Abate by
Apr 30, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:              On or about December 16, 2013, and at time prior thereto employees were exposed to an electrical shock hazard while using the Filtration Technology Systems Hot Melt Laminator (prototype).
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.305 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 10, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed:        On or about December 16, 2013, and at time prior thereto employees were exposed to an electrical shock hazard while using the breaker box  with missing breakers/ openings in the front of the main warehouse to turn lights of and on.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.305 G02 III

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 10, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:        a) On or about December 16, 2013, and at times prior thereto, employees were exposed to the electrical shock hazard of strain relief damage to electrical cords in use on the conveyor system the main production warehouse.        b) On or about December 16, 2013, and at times prior thereto, employees were exposed to the electrical shock hazard of strain relief damage to electrical cords in use on the hot melt laminator the main production warehouse.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339521528.