Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: REDWOOD VENTURES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REDWOOD VENTURES, INC. in 939/941 M STREET, NW, WASHINGTON, DC 20005 (NAICS 236116). OSHA activity number 339523623.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Redwood Ventures, INC. — free Get an email when a new federal OSHA severe-injury report for Redwood Ventures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
939/941 M STREET, NW
City
WASHINGTON
State
DC
ZIP
20005
Mailing
1434 PARK ROAD, NW, WASHINGTON, DC 20011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 3 instances 2 exposed
Issued
Jan 30, 2014
Abate by
Feb 5, 2014
Penalty
Initial $2,000 · Current $1,300 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     a) Roof of the Building - A laborer was observed without fall protection while on the roof positioning received materials exposing him to a 30 foot fall hazard, on or about 12/17/13.      b) 3rd Floor - A project supervisor and a laborer were observed walking past the unguarded edge of the stairway opening exposing them to a 10 foot fall hazard into the opening, on or about 12/17/13.      c) Top Floor Exiting onto Roof - A project supervisor and a laborer were observed walking past the unguarded edge of the stairway opening exposing them to a 10 foot fall hazard into the opening, on or about 12/17/13.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2000

1926.1052 C01 I

Serious Gravity 1 2 instances 2 exposed
Issued
Jan 30, 2014
Abate by
Feb 5, 2014
Penalty
Initial $1,200 · Current $800 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:       a)  Between the Basement and First Floors and Between the First and Second Floors - Project supervisor and a worker were observed using the stairs which was not equipped with a standard handrail exposing them to a 10 foot fall hazard, on or about 12/17/13.      Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1200

1926.1052 C01 II

Serious Gravity 1 2 instances 2 exposed
Issued
Jan 30, 2014
Abate by
Feb 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge:     a)  Between the Basement and First Floors and Between the First and Second Floors - Project supervisor and a worker were observed using the stairs which was not equipped with a standard stair rail exposing them to a 10 foot fall hazard, on or about 12/17/13.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339523623.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.